9. Insert the element fully to be sure permeate tube
completely enters internal cup.
10. Screw the cap back on.
11. Re-insert the RO Module back into the C- clamps.
12. Re-insert the black and blue tubing.
13. Snap the two "Double C" clamps back onto the RO
Module.
14. Re-install the DI module as described previously.
15. Follow the system restarting procedure on page 37.
Disinfecting the tank
After the RO Module replacement you must disinfect and
sterilize the storage tank. Carefully place a few drops of
regular household bleach into the tubing that connects the
outlet of the DI module with the storage tank before
connecting the tubing to the DI module. (As the tank fills
with water for the first time, it will be subjected to a
strong but continually diluting solution of chlorine.)
Alternate disinfection procedure:
a) Disconnect the tubing from the "T" connector on the
tank ball valve and remove the storage tank from
beneath the sink.
b) Wrap a towel around the ball valve and slowly
unscrew the valve from the storage tank. Water may
remain in the tank and it will escape when the valve
is removed. After setting the valve aside, place the
towel over the tank opening and shake and rotate the
tank to remove remaining water.
c) Re-wrap the threads with Teflon® pipe tape.
d) Now place a few drops of liquid chlorine bleach into
the top of the tank and re-install the tank ball valve (with
the valve in the closed position).
e) Reconnect the tubing to the swivel "T" connector.
36
© 2009-2016 Aquathin Corporation. All rights reserved.