Setup Of Main Program - JUKI AMB-289 Engineer's Manual

Computer-controlled, high-speed, single thread, chainstitch, button-neck-wrapping machine
Hide thumbs Also See for AMB-289:
Table of Contents

Advertisement

(3) Setup of main program

When you have purchased the single unit of IP-200 operation panel, the smart media card is packed together.
You can perform re-setup of the main program of MAIN circuit board on the control box side by using this
smart media card.
It is necessary that the main program and panel program have to match with each other.
If not, there is a possibility that trouble such as Error "E703 or E704" occurs. Be sure to perform setup by
using the smart media card which is packed together.
1. When panel program matches with main program
Perform the work by the procedure below when performing version-up of the main program by using the
smart media card.
1) First, turn ON the power.
2) Insert the smart media card into the operation panel.
3) Perform operation by the procedure displayed in the screen below.
Data edit screen
1) Press key 笊
Communication screen 1
2) Press key 笆 .
3) Press key 笳
.
Data selection screen
4) Press key 笘
5) Press key 笙
d
for three seconds.
.
.
86