● Mark a point (3) on the horizontal line C, 80 mm to the vertical reference line.
● Repeat this operation on the other side, checking that the two marks are on one horizontal line.
 Mark a point (3) on the horizontal line C, 80 mm to the vertical reference line.
 Repeat this operation on the other side , checking that the two marks are leveled.
Fix the brackets (optional):
● Drill holes at the marked points with a ɸ10 mm drill bit.
Fix the brackets (Optional):
● Insert the wall plugs 11 into the holes.
● Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) at the horizontal line A,
 Drill holes at the marked points with a ɸ10 mm drill bit.
 Insert the Wall Plugs 11 into the holes.
● Fix the chimney fixing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line B.
 Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) at the horizontal line A,
 Fix a Chimney fixing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line B.
Hook the hood body
Hook the hood body to the bracket 20.
Level the hood body itself.
Hook the hood body
Lock screws (M5*12) into the hood fixing bracket to prevent the hood body from accidentally sliding off.
Hook the hood body to the bracket 20.
Remove the filter from the inside of the hood body, and fix the screw 10 to wall plug 11 at the point
Level the hood body itself.
(3) (optional).
Lock screws (M5*12) on the hood fixing bracket to prevent the hood body from accidently sliding off .
Remove the filter,from the inside of the hood body, fix the screws 10 to Wall Plugs 11 at the points
(3)(optional).
CONNECTIONS
CONNECTIONS

DUCTED VERSION AIR EXHAUST SYSTEM

DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
When installing the ducted version, connect the hood to the chimney
chimney using either a flexible or a rigid pipe of ɸ 150 or ɸ 120 mm,
using either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of
the choice of which is left to the installer.
which is left to the installer.
● Insert the reducer flange 3 onto the hood body outlet to install a
 To install a ɸ 120 mm air exhaust connection, insert the reducer
flange 3 on the hood body outlet.
ɸ 120 mm air exhaust connection.
 Fix the pipe 4 in position using sufficient pipe clamps (not
● Fix the pipe 4 in place using sufficient pipe clamps (not
supplied).
supplied).
 Remove possible charcoal filters.
● Remove possible charcoal filters.
Right
Right
Wrong
Wrong