Mark a point (3) on the horizontal line C, 80 mm to the vertical reference line.
Repeat this operation on the other side and on the vertical reference line , checking that
the three marks are leveled.
Fix the brackets (Optional):
Drill holes at the marked points with a ɸ10 mm drill bit.
Insert the Wall Plugs 11 into the holes.
Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) at the horizontal line A,
Fix a Chimney fixing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line B.
Hook the hood body
Hook the hood body to the bracket 20.
Level the hood body itself.
Fix the exhaust pipe on the hood body.
Connect the Chimney fixing bracket 21 and Lower Decorative Chimney2.1
Fix the Chimney fixing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line A to prevent the
hood body from accidently sliding off the hood fixing bracket.
Right
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney
using either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of
which is left to the installer.
To install a ɸ 120 mm air exhaust connection, insert the reducer
flange 3 on the hood body outlet.
Fix the pipe 4 in position using sufficient pipe clamps (not
supplied).
Remove possible charcoal filters.
Wrong
6
B
A