Output (Master Device to Drive)
Byte
0
Operation Command (High Byte)
1
Operation Command (Low Byte)
2
Frequency Reference (High Byte)
3
Frequency Reference (Low Byte)
4
Reserved
5
<1> Unit depends on the setting of o1-03 (Digital Operator Display Scaling). When the drive is operating in the V/f
Control mode, the drive's output frequency becomes the input data.
<2> Data is displayed in units of either 0.01 A for drives 7.5 kW and smaller, or in units of 0.1 A for drives 11 kW and
larger. This is the same regardless of whether the drive is set for Normal Duty or Heavy Duty operation.
Output (Master Device to Drive)
Byte
0
Operation Command (High Byte)
1
Operation Command (Low Byte)
2
Frequency Reference (High Byte)
3
Frequency Reference (Low Byte)
4
5
6
Reserved
7
8
9
10
Analog Output Channel 1 (High Byte)
11
Analog Output Channel 1 (Low Byte)
12
Reserved
13
14
Digital Output (High Byte)
15
Digital Output (Low Byte)
16
MEMOBUS/Modbus Function Code
MEMOBUS/Modbus Starting Register
17
Address
(High Byte)
YASKAWA ELECTRIC TOBP C730600 23C 1000-Series Option SI-P3/V, SI-P3/T Installation Manual
7 PROFIBUS-DP Option Data and I/O Maps
Table 9 Basic Data Register Map Detail
Description
Table 10 Extended Data 1 Register Map
Description
<1>
<1>
<2>
<2>
Input (Drive to Master Device)
Byte
0
Drive Status (High Byte)
1
Drive Status (Low Byte)
2
Motor Speed (High Byte)
3
Motor Speed (Low Byte)
4
Output Current (High Byte)
5
Output Current (Low Byte)
Input (Drive to Master Device)
Byte
0
Drive Status (High Byte)
1
Drive Status (Low Byte)
2
Motor Speed (High Byte)
3
Motor Speed (Low Byte)
4
Torque Reference Monitor (High Byte)
5
Torque Reference Monitor (Low Byte)
6
Reserved
7
8
Frequency Reference (High Byte)
9
Frequency Reference (Low Byte)
10
Output Frequency (High Byte)
11
Output Frequency (Low Byte)
12
Output Current (High Byte)
13
Output Current (Low Byte)
14
Analog Input Channel 1 (High Byte)
15
Analog Input Channel 1 (Low Byte)
16
MEMOBUS/Modbus Function Code
MEMOBUS/Modbus Starting Register
17
Address
(High Byte)
Description
<1>
<1>
<2>
<2>
Description
<3>
<3>
<4>
<4>
<5>
<5>
29