Item
Description
8
UID button/LED
9
Power On/Standby button and system power
LED (Server 3)
1
When the LEDs described in this table flash simultaneously, a power fault has occurred.
2
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has
occurred, or the front I/O cable is disconnected.
3
If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the system health
status.
24 SFF with expander daughter board LEDs
Item
Description
1
Expander daughter board power good LED
2
Expander daughter board power fault LED

Power fault LEDs

The following table provides a list of power fault LEDs, and the subsystems that are affected. Not all
power faults are used by all servers.
16
Power fault LEDs
1
1
Status
Solid blue = Activated Flashing blue:
• 1 flash per second = Remote management or
firmware upgrade in progress
• 4 flashes per second = iLO manual soft
reboot sequence initiated
• 8 flashes per second = iLO manual hard
reboot sequence in progress
Off = Deactivated
Solid green = System on
Flashing green = Performing power on
sequence Solid amber = System in standby
2
Off = No power present
Status
Solid green = Expander daughter board power
is good
Off = Expander daughter board power fault
LED will be on
Solid yellow = Expander daughter board power
fault has occurred
Off = Expander daughter board power good
LED will be on