Exterior Wash 120
Light source ......................................................... 9 x 2800 K warm white and 9 x 6500 K cold white LEDs
Half-peak beam angle .............................................................................................................................. 7°
Beam angles available with accessory diffusers ............................................. 12°, 21°, 40°, 60°, 12° x 60°
Construction
Protection rating ................................................................................................................................... IP66
Color .......................................................................... Clear anodized (standard), black or white (optional)
Housing ............................................................................................................................... Cast aluminum
Effective Projected Area (EPA) ........................................................................................ 0.05 m² (0.54 ft
Impact resistance ................................................................................................................................. IK08
RoHS ........................................................................................................................................... Compliant
Installation
Orientation ............................................................................................................................................. Any
Mounting ............................................................................................................................. Adjustable yoke
Minimum distance to illuminated surfaces .............................................................................. 0.2 m (0.6 ft.)
Connections
Power connection ....................................................................... 1.8 m (5.9 ft.) cable tail without connector
Data I/O ........................................................................... 1.8 m (5.9 ft.) open ended 5-conductor cable tail
Cable entry ........................................................................................................................ IP68 cable gland
Electrical
AC power ................................................................................................ 100-240/277 V nominal, 50/60 Hz
Power supply unit ............................................................................ Integrated, auto-sensing multi-voltage
Maximum total power consumption ..................................................................................................... 50 W
Typical half-cycle RMS inrush current at 240 V, 50 Hz ........................................................................ 9.7 A
Typical power and current
Exterior Wash 100
100 V, 60 Hz .............................................................................................................. 0.5 A, 42 W, PF 0.99
120 V, 60 Hz .............................................................................................................. 0.4 A, 42 W, PF 0.99
230 V, 50 Hz .............................................................................................................. 0.2 A, 42 W, PF 0.93
277 V, 60 Hz .............................................................................................................. 0.2 A, 42 W, PF 0.85
Exterior Wash 110
100 V, 60 Hz .............................................................................................................. 0.5 A, 42 W, PF 0.99
120 V, 60 Hz .............................................................................................................. 0.4 A, 42 W, PF 0.99
230 V, 50 Hz .............................................................................................................. 0.2 A, 42 W, PF 0.96
277 V, 60 Hz .............................................................................................................. 0.2 A, 42 W, PF 0.90
Exterior Wash 120
100 V, 60 Hz .............................................................................................................. 0.5 A, 43 W, PF 0.99
120 V, 60 Hz .............................................................................................................. 0.4 A, 43 W, PF 0.99
230 V, 50 Hz .............................................................................................................. 0.2 A, 43 W, PF 0.97
277 V, 60 Hz .............................................................................................................. 0.2 A, 43 W, PF 0.90
Measurements made with fixture in steady state at nominal voltage, ambient temperature (Ta) 20° C
(68° F), all LEDs at full intensity. Allow for a deviation of +/10%.
Thermal
Cooling ...................................................................................................................................... Convection
Maximum ambient temperature (Ta max.) ........................................................................... 45° C (113° F)
Minimum ambient temperature (Ta min.) ............................................................................. -30° C (-22° F)
Power must be maintained below -20° C (-4° F)
Maximum surface temperature, steady state, at 45° C ambient ........................................... 70° C (158° F)
Total heat dissipation (calculated, +/- 10%) .............................................................................. 170 BTU/hr.
TM