HOLD LAST LOOK: Fixture holds and displays the last received DMX command (fixture must be set to
MASTER).
If the fixture is set to MASTER and it does not receive a control signal, it will continue to obey the last
DMX command that it received.
If the fixture is set to SLAVE and it does not receive a control signal, it will black out until it receives a
control signal.
BLACK OUT (default): Fixture blacks out.
If the fixture is set to MASTER and it does not receive a control signal, it will black out until it receives
a control signal.
If the fixture is set to SLAVE, it will always black out if it does not receive a control signal.
These options also apply if a fixture is receiving a control signal but that signal is suddenly lost.
To set a fixture's offline behavior:
1.
Access the control menu and scroll to FIXTURE CONFIG. Press ENTER.
2.
Scroll to MASTER/SLAVE and press ENTER. Press UP or DOWN to select master or slave operation
as explained above and press ENTER to confirm. Press MENU to go back up one level.
3.
Scroll to DMX STATE and press ENTER. Press UP or DOWN to select SHOW MODE, HOLD LAST
LOOK or BLACK OUT as explained above and press ENTER to confirm.
Display lock – password protection
If you want to reduce the risk of unauthorized access to the control menus, you can set the fixture to
require a user password before the control panel becomes operative. Password protection is disabled by
default. You can enable or disable password protection as follows:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select DISPLAY LOCK and press ENTER.
3.
Select YES to enable password protection or NO to disable it. Press ENTER.
You can set the user password to a value of your choice. See below.
Control menu passwords
The factory default user password is 123. The service password is 111. The user password can be reset
to any value from 0 to 999 as described below. The service password cannot be reset. To change the user
password:
1.
Press and hold the MENU button to access the control menu.
2.
If prompted for a password, press the arrow buttons to scroll to the current 3-digit password or the
service password (111). Press ENTER when the password is displayed.
3.
Select FIXTURE CONFIG from the main menu and press ENTER.
4.
Select LOCK PASSWORD and press ENTER.
5.
Press the UP or DOWN arrow button to scroll to the desired password. Press ENTER to save it.
6.
Record your password inside the front cover of this manual.

Factory reset

To reset all user settings to factory defaults:
1.
Access the control menu and select FIXTURE CONFIG. Press ENTER.
2.
Select FACTORY RESET and press ENTER.
3.
Select YES and press ENTER to confirm, or MENU to escape.