Page 2
Martin™, RUSH™, JEM™ and other trademarks mentioned herein are registered as the property of Harman International Industries. Martin Professional • Olof Palmes Allé 18 • 8200 Aarhus N •Denmark • www.martin.com Manual: Revision C...
Table of contents Safety information ..................... 4 Introduction ....................... 8 Features at a glance ..................8 Before using the product ................8 Fog machine overview ..................9 Physical installation ..................10 Mounting the fog machine on a truss ............10 Securing with a safety cable ................
Keep this user manual for future use. For the latest user documentation and other information for this and all Martin™ products, please visit the Martin website at http://www.martin.com If you have any questions about how to install, operate or...
Page 5
Martin™ distributor (see www.martin.com/distributors for details) or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180. Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fog machine.
Page 6
If the fog machine is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a secondary attachment such as a safety cable that will hold the RUSH SM 850 User Manual...
Page 7
Protection from breathing problems A fog machine can operate safely only with the fog fluid it is designed for. Use only fluid that is approved by Martin™ (see ‘Approved Fluids on page Error! Bookmark not defined.) with this machine. Other fluids may cause the release of toxic gases, presenting a severe health hazard.
LED-illuminated fluid container, automatic pump shut-off, and a convenient carrying handle, the RUSH SM 850 is an ideal companion for mobile DJs and bands, and effective in small venues.
Fog machine overview mounting bracket power switch clamp attachment point remote control socket fluid tank remote control socket secondary attachment point AC power socket “No fluid” light fog output nozzle RUSH SM 850 User Manual...
The fog machine is designed for indoor use only and must be used in a dry location with adequate ventilation. Martin™ can supply suitable safety cables and rigging clamps for use with the fog machine (see ‘Accessories’ on page 19).
AC voltage is appropriate for the range indicated on page 18 and on the machine’s rear panel. If your AC voltage is outside the specified range, do not use the fog machine. RUSH SM 850 User Manual...
Flip the switch that corresponds to the desired transmitter button to the ON position. Flip all other switches to OFF. The fog machine responds to all buttons for which the DIP switch is in the ON position. RUSH SM 850 User Manual...
“No Liquid” rear panel LED illuminates when fluid is exhausted and the pump is automatically disabled. 6. When finished, turn off the machine and allow it to cool before handling. The nozzle remains hot for three hours. RUSH SM 850 User Manual...
The user may carry out the service operations described in this manual. All other service operations must be carried out by an authorized Martin™ service technician. Do not try to repair the fog machine yourself, as you may create a safety risk or cause damage that is not covered by the product warranty.
Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents, giving owners access to Martin’s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product’s lifetime.
Troubleshooting This section describes possible problems and provides some suggestions for ™ easy troubleshooting. Refer the machine to an authorized Martin service technician if the suggested remedies do not solve the problem. Symptom Potential cause Remedies Main fuse blown Replace fuse (see page 14)
Weight, dry ................7.3 kg (16.1 lbs.) Weight, filled ............... 8.9 kg (19.7 lbs.) Performance Coverage volume ............ 200 m (7062 ft ) minute Maximum operating time at full output .........45 seconds Ready time ..................8 minutes RUSH SM 850 User Manual...
Page 18
Maximum ambient temperature (T max.) ......40° C (104° F) Minimum ambient temperature (T min.) ........5° C (41° F) Exterior surface temperature, steady state ......50° C (122° F) Max. nozzle temperature ............300° C (572° F) RUSH SM 850 User Manual...
Accessories Approved Fluids* RUSH Fog Fluid™ JEM Pro Clean Supreme™ *Various sizes available - contact your dealer or see www.martin.com for details. Installation Accessories Half-coupler clamp ..............P/N 91602005 G-clamp (vertical hanging suspension only) ......P/N 91602003 Quick-trigger clamp (vertical hanging suspension only) ..P/N 91602007 Safety cable, SWL 60 kg, BGV C1/ DGUV 17, black .....
Page 20
Disposing of this product Martin™ products are supplied in compliance with Directive 2012/19/EC of the European Parliament and of the Council of the European Union on WEEE (Waste Electrical and Electronic Equipment), where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life.
Need help?
Do you have a question about the RUSH SM 850 and is the answer not in the manual?
Questions and answers