Danfoss MCO 351 Operating Instructions Manual page 14

Positioning controller vlt automationdrive fc 301/302
Hide thumbs Also See for MCO 351:
Table of Contents

Advertisement

Electrical Installation
Digital inputs
12
+24 V OUT
13
+24 V OUT
18
Reference index bit 0
19
Reference index bit 1
27
Enable (error clear in digital control mode)
29
Reference index bit 4
4
4
32
Reference index bit 3
33
Reference index bit 2
20
COM D in
37
Safe Torque Off (STO)
Table 4.1 Digital Inputs
Relay 1:
Mechanical brake (normally open)
Relay 2:
Mechanical brake monitoring (normally closed)
Analog input:
53 ±10 V-In Manual jog positive
54 ±10 V-In Manual jog negative
55 Common for analogue inputs
Supply voltage:
12, 13 +24 V Out
20 Common for digital inputs (common with X55/4-X56/4-
X58/2)
12
Operating Instructions
Danfoss A/S © 04/2014 All rights reserved.
MG33R302

Advertisement

Table of Contents
loading

Table of Contents