Passage Time

Passage time is used in Door Contact Mode. Using Passage Time; it is possible to stop
the Universal Sensor from sending door events to the Tunstall Lifeline or Telecare
Overlay System for a maximum of 120 seconds, (this time is definable in the
"Advanced
Mode"). After the Passage Time has elapsed the Universal Sensor will
start to send radio messages to the Tunstall Home Unit.
Whilst the Universal Sensor is assigned and operating as a Door
Contact Sensor press and hold the "Select Button" and the "Back
Button" together for 3 seconds.
The red LED will flash every 2 seconds and the Universal Sensor
will begin counting down until it will begin monitoring and
sending alarms to the Tunstall Home Unit.