10.2.1 Alarms relative to the auto-level system

The S40 SELETRON has a water refilling system that is managed by three electronic sensors*:
The minimum level sensor checks the presence of a minimum quantity of water in the boiler that is sufficient to cover the elements of
the electrical resistances.
The * level sensor determines the level of water in the boiler preset by the manufacturer.
The maximum level sensor checks that the level of water in the boiler is not higher than that allowed.
When the water in the boiler does not reach the level of the minimum level sensor, the display visualises:
When the water in the boiler reaches the level of the minimum level sensor, the level indicator visualises:
When the water in the boiler reaches the level preset by the manufacturer, the level indicator visualises:
When the water in the boiler reaches the level of the maximum level sensor, the level indicator visualises:
* The electronic level sensor can be replaced by a mechanical/electrical float on request.
BOILER REFILL FAILED, PUSH OK alternating with LOW WATER LEVEL IN THE BOILER
This alarm blocks the machine and can be reset by pressing the "OK" key.
This alarm intervenes when the refilling of the water in the boiler has exceeded the run time of the programmed time-out (6 minutes)
and the water in the boiler has not reached the minimum level sensor.
Press the "OK" key to activate a second refilling cycle.
BOILER REFILL FAILED, PUSH OK
This alarm does not block the machine and can be reset by pressing the "OK" key.
This alarm intervenes when the refilling of the water in the boiler has exceeded the run time of the programmed time-out (6 minutes).
Press the "OK" key to activate a second refilling cycle.