ALARMS CONTROL - ELETTRIK – SELETRON MODELS
NOTE. The alarm messages can be divided into two different types: blocking and non-blocking alarms.
A00
Loss of data
This alarm is not a blocking one.
It appears when the control board has lost the parameters set by the installer; therefore, the appliance will
continue to operate but with default settings. Enter new TEMPERATURE parameter settings to cancel
this alarm (the SELETRON model will also require DOSE settings). If the problem persists, it is necessary
to replace the control board.
High temperature
A01
This is a blocking alarm.
If the coffee machine reaches 135 °C, for any reason, this alarm appears and blocks all functions of the
machine. This alarm automatically disappears when temperature drops to below 130 °C, thus reactivating
all functions of the machine. Make sure the appliance has sufficient air circulation.
A02
Damaged probe
This is a blocking alarm.
This alarm signals that the boiler temperature probe is out of range.
Alternatively to A02, the display may indicate:
"UFL" if the probe is reading a temperature below 0 °C or the probe is disconnected.
"OFL" if the probe is reading a temperature higher than 140 °C or if the probe is short circuited.
In both cases check the temperature probe connections to the electric control board and replace the probe.
A03
Damaged automatic water refill system
This is a blocking alarm.
This alarm signals that the automatic water refill system of the boiler has been on for more than 4 minutes.
To cancel this alarm switch off the appliance for a while using the main switch (3). Check the boiler filler
system, should this alarm appear again.
A04
Free-flow delivery time-out
This is not a blocking alarm.
This alarm signals that the 1st delivery group from the right has been switched on for more than 4 minutes.
To cancel this alarm, press the button causing the group to block again (the LED of this button will flash
during the block).
A05
Free-flow delivery time-out
This is not a blocking alarm.
This alarm signals that the 2nd delivery group from the right has been switched on for more than 4 minutes.
To cancel this alarm, press the button causing the group to block again (the LED of this button will flash
during the block).
A06
Free-flow delivery time-out
This is not a blocking alarm.
This alarm signals that the 3rd delivery group from the right has been switched on for more than 4 minutes.
To cancel this alarm, press the button causing the group to block again (the LED of this button will flash
during the block).