Chap. 6 Alarm Management; No Water In The Tank; Failure In Water Dosing System For Coffee; Boiler Temperature Reading System Failure (Only With Boiler Switched On) - La Spaziale S1 Mini Vivaldi Instruction Manual

Table of Contents

Advertisement

6
6.1

NO WATER IN THE TANK

The lack of water in the tank (4) is signalled by the red control light (21) on the control panel (9), which
will switch on. Fill the tank with at least 1 litre of cold drinking water (the tank can hold up to 3 litres of
water).
6.2

FAILURE IN WATER DOSING SYSTEM FOR COFFEE

This alarm means that the water dosing system for delivery coffee has an anomaly. There could be a flow
meter operation failure or the coffee may be too finely ground. The alarm is signalled by the control lights
14-15-16, which will switch on if a one-cup coffee dose is being delivered or by the control lights 17-18-19
if a two-cup coffee dose is being delivered.
The appliance will continue to deliver coffee without stopping at the set dose. To stop the coffee delivery
operation, press the 1-coffee (24) or 2-coffee (25) button.
If this alarm occurs, contact an authorised technical assistance centre.
6.3
BOILER TEMPERATURE READING SYSTEM FAILURE
(Only with boiler switched on)
This is a blocking alarm and it is signalled by the control lights 19-20-21, which remain lit.
This alarm occurs when the temperature exceeds 145°C (temperature probe short circuit) or when it is
less than 60°C (temperature probe disconnected).
To cancel the alarm will occur from the display, switch off the boiler by pressing the button 26; the appliance
can continue to operate with the boiler switched off.
If this alarm occurs, disconnect the appliance from the mains power and call an authorised technical
assistance centre.
6.4
BOILER TEMPERATURE READING SYSTEM FAILURE
This is a blocking alarm and it is signalled by the control lights 20-21, which remain lit.
This alarm ocurs when the temperature exceeds 145°C (temperature probe short circuit) or when it is less
than 60°C (temperature probe disconnected).
When the appliance is first switched on, if the temperature has not exceeded 60°C after 5 minutes, the
alarm will occur.
If this alarm occurs, disconnect the appliance from the mains power and call an authorised technical
assistance centre.
6.5
FAILURE IN BOILER HEATING ELEMENT PILOTING DEVICE (TRIAK)
(Only with boiler switched on)
This is a blocking alarm and it is signalled by the control lights 19-20-21, flashing. This alarm occurs when
the temperature exceeds 140°C (triak in constant operation).
If this alarm occurs, disconnect the appliance from the mains power and call an authorised technical
assistance centre.
20
LSC 014 -UK- REV. 01
ALARM MANAGER
INSTRUCTION MANUAL