Annex B

B.
Annex B
B.1

Certification

B.1.1

CE Marking

CE marked frequency inverter and servo drives were developed and manufactured to comply
with the regulations of the Low-Voltage Directive 2006/95/EC.
The inverter or servo drive must not be started until it is determined that the installation com-
plies with the Machine directive (2006/42/EC) as well as the EMC-directive (2004/108/EC)
(note EN 60204).
The frequency inverters and servo drives meet the requirements of the Low-Voltage Directive
2006/95/EC. They are subject to the harmonized standards of the series EN 61800-5-1.
This is a product of limited availability in accordance with IEC 61800-3. This product may
cause radio interference in residential areas. In this case the operator may need to take cor-
responding measures.
B.1.2

UL Marking

To be conform according to UL for use on the North American and Canadian Market the fol-
lowing additionally instructions must be observed (original text of the UL-File):
• Suitable For Use On A Circuit Capable Of Delivering Not More Than
10000 rms Symmetrical Amperes, 240 or 480 Volts Maximum" when
"Protected by Fuses" see Instruction Manual for specific fuse details
and Alternate Branch Circuit Protection details".
• Maximum Surrounding Air Temperature 45 °C (113 °F)
• For control cabinet mounting as „Open Type"
• Use in a Pollution Degree 2 environment
• Use 60/75°C Copper Conductors only
• Motor protection by adjustment of current parameters. For adjustement
see application manual parameters Pn.14 and Pn.15
• Motor Overtemperature Protection:
These drive models are not provided with load and speed sensitive
overload protection and thermal memory retention up on shutdown
or loss of power (for details see NEC, article 430.126(A)(2)".
• Only for use in WYE 480V/277V supply sources
• Overload protection at 130 % of inverter output rated current (see
type plate)
• Operator and Control Board Rating of relays (30Vdc.:1A)
30
Acceptance according to UL is marked at KEB inverters with the adjacent
logo on the type plate.