2.9.6 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 4)

Here following is a procedure of connecting to a 100-pin 0.65-mm-pitch foot pattern on the user system using the M3T-FLX-
100NRB (not included). For details on the M3T-100LCC-DMS (not included) and M3T-FLX-100NRB (not included), refer to
each user's manual.
(1) Attach the NQPACK100RB included with the M3T-FLX-100NRB to the user system.
(2) Attach the YQPACK100RB included with M3T-FLX-100NRB to the NQPACK100RB and secure it with the YQ-
GUIDE's.
(3) Attach the M3T-FLX-100NRB to the YQPACK100RB.
(4) Attach the M3T-100LCC-DMS to the M3T-FLX-100NRB
(5) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT2-EPB.
(6) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 2.13 Connecting to a 100-pin 0.65-mm-pitch foot pattern (Part 4)
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
The connectors of the M3T-100LCC-DMS and M3T-FLX-100NRB are guaranteed for only 20
insertion/removal iterations.
REJ10J0868-0200 Rev.2.00 January 16, 2006
*
These corners are not round.
*: These four products are available in one package.
M3T-FLX160-EPB
M3062PT2-EPB
CN2 side
(5)
M30800T-PTC
M3T-100LCC-DMS
(6)
(not included)
M3T-FLX-100NRB
(not included)
(4)
YQ-GUIDEs (x4)
(3)
YQPACK100RB
(2)
NQPACK100RB
Flash version MCU etc.
100-pin 0.65-mm-pitch
(PRQP0100JB-A) foot pattern
(1)
No. 1 pin
User system
CAUTION
Evaluation with
actual MCU
HQPACK100RB168
(not included)
2. Setup