2.9.3 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 1)

Here following is a procedure of connecting to a 100-pin 0.65-mm-pitch foot pattern on the user system using the M3T-F160-
100NRB (not included). For details on the M3T-F160-100NRB (not included), refer to its user's manual.
(1) Attach the NQPACK100RB included with the M3T-F160-100NRB to the user system.
(2) Attach the YQPACK100RB included with the M3T-F160-100NRB to the NQPACK100RB and secure it with the YQ-
GUIDE's.
(3) Attach the CN2 side of the M3T-F160-100NRB to the J4 side of the M3062PT2-EPB.
(4) Attach the M3T-F160-100NRB to the YQPACK100RB.
These corners are not round.
*: These four products are available in one package.
Figure 2.10 Connecting to a 100-pin 0.65-mm-pitch foot pattern (Part 1)
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The connectors of the M3T-F160-100NRB are guaranteed for only 50 insertion/removal iterations.
REJ10J0868-0200 Rev.2.00 January 16, 2006
M3062PT2-EPB
(3)
(4)
*
YQPACK100RB
(2)
NQPACK100RB
(1)
No. 1 pin
CAUTION
M3T-FLX160-EPB
CN2 side
M3T-F160-100NRB
(not included)
Evaluation with
actual MCU
HQPACK100RB168
(not included)
YQ-GUIDE (x4)
Flash version
MCU etc.
100-pin 0.65-mm-pitch
(PRQP0100JB-A) foot pattern
User system