M3062PT2-EPB User's Manual

2.9.2 Connecting to a 100-pin LCC Socket

Here following is a procedure of connecting to a 100-pin LCC socket (IC61-1004-051 of Yamaichi Electronics Co., Ltd.) on
the user system using the included M30800T-PTC.
(1) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT2-EPB.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
Figure 2.9 Connecting to a 100-pin LCC socket
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.
http://www.yamaichi.co.jp/e/index.shtml
REJ10J0868-0200 Rev.2.00 January 16, 2006
M3T- FLX160- EPB
M 3062PT2- EPB
CN 2 side
(1)
M 30800T- PTC
100- pin LCC socket
(2)
No . 1 pin
User System