Troubleshooting; Flowchart To Remedy The Troubles - Renesas Emulation Probe for M32C/88 Group M30880T-EPB User Manual

Emulation probe for m32c/88 group
Table of Contents

Advertisement

M30880T-EPB User's Manual

5. Troubleshooting

This chapter describes how to troubleshoot when this product does not work properly.

5.1 Flowchart to Remedy the Troubles

Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tools Homepage.
Init dialog box of emulator
Program window of emulator
Emulator debugger startup completed
Figure 5.1 Flowchart to remedy the troubles
REJ10J0497-0100Z Rev.1.00 January 16, 2005
http://www.renesas.com/en/tools
Turning on emulator
Front panel LED
of emulator
Normal
debugger displayed
Normal
EMEM dialog box of
emulator debugger
Normal
debugger displayed
Normal
Not normal
1. Check connection of the power supply cable.
"
See
2.5 Connecting the Power Supply for the Emulator"
(page 23).
2. Check that the power is properly supplied to the user
system.
"
See
Turning ON the Power
Not normal/Error displayed
1. Check the operating environment etc. of the emulator
debugger.
'
See the user
s manual of the emulator debugger.
2. Reinstall the emulator debugger.
Not normal/Error displayed
See "5.2 (2) EMEM Dialog Box Does Not Appear at
Debugger Startup" (page 94).
Error displayed
See "5.2 (3) Errors Occur at Debugger Startup" (page 95).
"
(page 24).
5. Troubleshooting
Page 92 of 100