JSON
ifcounters.json
GET network/ifcounters.json?port=<port>
Valid values for the argument <port> are 0, 1, and 2.
Valid values for the argument <port> are 0, 1, and 2.
Port number 0 option refers to the internal port (CPU port).
Port number 2 option is only valid if two Ethernet ports are activated in the module.
Name
inoctets
inucast
innucast
indiscards
inerrors
inunknown
outoctets
outucast
outnucast
outdiscards
outerrors
Anybus CompactCom 40 EtherNet/IP Network Guide
Data Type
Description
Number
IN: bytes
Number
IN: unicast packets
Number
IN: broadcast and multicast packets
Number
IN: discarded packets
Number
IN: errors
Number
IN: unsupported protocol type
Number
OUT: bytes
Number
OUT: unicast packets
Number
OUT: broadcast and multicast packets
Number
OUT: discarded packets
Number
OUT: errors