Signals Of Leds On The Control Unit - Nice RD400 Instructions And Warnings For Installation And Use

For sliding gates
Hide thumbs Also See for RD400:
Table of Contents

Advertisement

8 flashes
Command already present.
1-sec pause
8 flashes
10 flashes
Manoeuvre time-out or lack of
1-sec pause
motor power during the position
10 flashes
recognition phase

9.2 - Signals of LEDs on the control unit

The control unit contains LEDs that can emit
special signals both during normal operation
and in case of anomalies.
OK LED
Red and green LED off
Green or red LED on
1 green flash per second
2 quick green flashes
Series of red flashes separated
by a 1-second pause
STOP LED (red)
OFF
On
L1
Off
On
Flashes
L2
OFF
On
Flashes
L3
OFF
On
Flashes
L4(R) (radio)
On
Flashes
Another command is already present. Remove the command present to be able to
send other commands.
The time-out denotes that the manoeuvre is too long. Shorten the manoeuvre time by
increasing the speed or balancing the gate to reduce the motor's effort. If the motor
lacks power check whether the board is properly inserted in its housing
9
L4(R)
L3
L2
L1
Stop/Set
Close
Open
Table 18 - Terminal LEDs (Fig. 9)
Cause
Fault
Serious fault
All OK
Input status variation
Various
Cause
Input intervention
STOP
All OK
Table 19 - Button LEDs (Fig. 10)
Description
During normal operation it indicates "Short slowdown"
During normal operation it indicates "Long slowdown"
Function programming in progress
Description
During normal operation it indicates slow "Motor speed"
During normal operation it indicates fast "Motor speed"
- Function programming in progress
- If it flashes together with LEDs L1 and L3, the user must run the recognition phase of the gate opening
and closing positions (Paragraph 7.3).
Description
During normal operation the device indicates "Automatic Closing" is inactive.
During normal operation the device indicates "Automatic Closing" is active.
- Function programming in progress
- If it flashes together with LEDs L1 and L2, the user must run the recognition phase of the gate opening
and closing positions (Paragraph 7.3).
Description
During normal operation it indicates that a radio code not present in the memory has been received.
Transmitter programming or deletion under way
Solution
Make sure there is power supply; check to see whether the fuses are blown;
if necessary, identify the reason for the failure then replace them with others
of the same type.
Try switching off the control unit for a few seconds; if the condition persists,
it means that there is a malfunction and the electronic circuit board has to
be replaced.
Normal control unit operation.
This is normal when there is a change in one of the inputs: SbS, STOP, inter-
vention of photocells or the radio transmitter is used.
Same signal on the warning light or courtesy light: see Table 20
Solution
Check the devices connected to the STOP input
STOP input active
10
L4(R)
L3
L2
Close
Stop/Set
Open
L1
English – 21