8b
5.2 - Connecting the automation to the mains electricity
WARNING! – The automation must be connected to the mains electricity by an expert and qualified electrician, in accordance
with established laws, standards and local regulations.
Proceed as described below
01.
Manually release the gearmotor so that the gate can be opened and closed
02.
Move the gate leaf to the halfway position of its path
03.
Manually lock the gearmotor
04.
Power the automation and verify:
- that the motor is not moving
- that the OK LED (green) flashes regularly at the frequency of one flash per second
- that the warning light connected to the FLASH output is off
ON
if any of these conditions are not satisfied, proceed as follows (Step 05)
05.
Disconnect the automation from the mains power and check the electrical connections, photocell alignment and fuses. Consult Chapter
10 (Troubleshooting) if necessary
8
7
6
5
4
3
2
1
L1
L2
L3
2
OFF
FLASH
English – 11