Programming; Programming Buttons; Quick Set-Up; Programming 7.1 - Programming Buttons - Nice RD400 Instructions And Warnings For Installation And Use

For sliding gates
Hide thumbs Also See for RD400:
Table of Contents

Advertisement

06.
The force adjustment is an important safety factor and must be done with the utmost care by qualified technicians. Important! - Adjust
the force sufficiently to enable the gate to move as intended; higher force values to those necessary for moving the gate can cause injury
to animals and persons or damage to property if the gate collides with an obstacle
07.
Before commissioning the automation, adequately inform the owner in writing regarding the attendant residual risks
7

PROGRAMMING

7.1 - Programming buttons

A number of programmable functions are available on the ROAD control unit; they can be adjusted using 4 buttons on the control unit and are
displayed through 4 LEDs: L1, L2, L3, L4(R).
The default settings should satisfy most requirements, but can be modified at any time using the appropriate programming procedure; see
Paragraph 7.6.
Buttons
Function
The "OPEN" button enables the user to control opening of the gate or move the program-
Open
s
ming point upwards.
Stop /
The "STOP" button can be used to stop the manoeuvre; if pressed for more than 3 sec-
Set
onds, it allows for entering the programming mode, as described below.
The "CLOSE" button enables the user to close the gate or move the programming point
Close
t
downwards.
Radio
The "RADIO" button allows for memorising and deleting the transmitters to be used with
ROAD.

7.2 - QUICK SET-UP

The "Quick set-up" function allows for speeding up the motor's commissioning. It only works with an empty memory.
This procedure allows for detecting and memorising the STOP input configuration, the presence or absence of the connection in "Phototest"
mode of the PHOTO input, the opening and closing positions and the transmitter (if present) memorised in Mode 2 with the Step-by-Step control.
Memorisation procedure
01.
Move the gate leaf to the halfway position of its path
02.
Lock the gearmotor
03.
Set the direction in relation to the gearmotor's position with respect to the
gate leaf
04.
Power the control unit through the mains and wait 10 seconds
05.
Press and release s
06.
Device recognition phase:
LEDs L2 and L3 flash rapidly for the entire duration of the recognition phase
and the gate performs the closing, opening and closing manoeuvres
06.
LED L4(R) flashes once every second: press and release the button of the
transmitter to be memorised
If the memorisation procedure was successful, LED L4(R) on the control unit
will flash 3 times.
Repeat the procedure for each transmitter to be memorised.
The memorisation phase terminates if no further transmitters are memorised
for 10 seconds.
Table 6 - Procedure for Quick set-up
see Paragraph 5.1
10 s
L2 and L3
L4(R)
...
L4(R)
English – 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents