03.
Release the STOP button
This procedure must be repeated if a modification is made to the
devices connected to the "STOP Safety Edge" terminal (for example,
after connecting a new device to the control unit).
After performing the recognition of the safety devices on the automated sys-
tem, the control unit must recognise the gate Opening and Closing positions.
CAUTION! - The recognition procedure of the safety devices and the
gate Opening and Closing positions must be done consecutively, without
interruption. You can not perform the recognition of the safety devices at
one time and the recognition of the positions at another time.
7.10.1 - Recognition of the Opening and Closing positions with
mechanical limit switch
You can program 2 positions, as follows:
Position
Meaning
Opening
Maximum opening position. When the gate reaches
this position it stops.
Closing
Maximum closing position. When the gate reaches this
position it stops.
Caution! - If the direction of rotation does not correspond to the direc-
tion set (Open button = opening direction), you need to invert the "V"
and "W" connections (phase inversion) in the motor connector (Fig. 18).
To perform the procedure, proceed as follows:
01.
Move DIP switch 1 to OFF
02.
Press the "Open" button to move
the gate to its maximum open po-
sition
03.
Press the "Close" button to move
the gate to its maximum closed
position
CAUTION! – The recognition phases must not be interrupted. If there
is an interruption, you must repeat the entire recognition process. If at
the end of the recognition phase, the red LED flashes 9 times-pause-9
times, it means that an error has occurred.
If instead it flashes 3 times-pause-3 times, reset the error by pressing
the STOP button and invert the opening limit switch connection with
that of the closing limit switch at the LIMIT SWITCH terminal (Fig. 14).
The position recognition phase can be repeated at any time, also after
the installation.

7.11 - Operating modes

CAUTION! - If the functions of Table 3 are programmed with the Oview
programming unit, it is necessary to set the dip switches to OFF.
DIP1 DIP2 DIP3 DIP4 Function
OFF
OFF
OFF
OFF
Hold-to-run movement
ON
x
OFF
OFF
Acquisition of positions and status of the ALT
input
OFF
ON
OFF
OFF
Rotation direction of the encoder reversed
OFF
x
OFF
ON
Industrial mode (semi-automatic opening –
hold-to-run closing), if positions recognised
OFF
x
ON
OFF
Semi-automatic mode, if positions recognised
OFF
x
ON
ON
Automatic mode with adjustable pause time, if
positions recognised (see para. 10.1.2 "Other
functions" for info on saving the pause time)
TABLE 3
18

7.12 - Oview programming unit

Using the Oview programming unit allows you to manage the installation,
maintenance and diagnosis of the entire automated system in a thorough and
rapid manner.
You can connect Oview to the control unit via the IBT4N interface using a bus
cable with 4 wires inside.
To access the BusT4 connector, you need to open the control unit box, plug
the IBT4N connector into the appropriate slot and then connect the Oview
programmer (Fig. 19).
Oview can be used at a maximum cable distance of 100 metres from the
control unit; it can be connected simultaneously to multiple control units (up to
16) and can remain connected even during normal operation of the automated
ON
OFF
system. When working with Oview, it is very important to observe the instruc-
tions in the Oview instruction manual.
If there is an OXI radio receiver in the control unit, when you use Oview you can
have access to the parameters of the transmitters memorised in the receiver.
For further information, refer to the Oview instruction manual or the control unit
function sheet available from the website www.niceforyou.com
CAUTION! - If the functions of Table 3 are programmed with the Oview
programming unit, it is necessary to set the dip switches to OFF.
19
1
2
3
OFF
4
ON
English – 13