Rs-232C Serial Communication Problem - Sam4s NR-500R Service Manual

Electronic cash register, nr-500 series
Hide thumbs Also See for NR-500R:
Table of Contents

Advertisement

8-7 RS-232C Serial Communication Problem

RS-232C Problem
Loop Back
Failure?
N
Communication
Failure?
N
H/W Handshake
Ok?
Y
End
SAM4S NR-500 SERIES
1. Perform the "SELF TEST" in the S-MODE using the Loop
Back test Connector.
2. Check the connection of the RS-232C Connector and Loop
Y
Back Connector.
3. Check the TXD,RXD, DTR, DSR Pin on CPU.
4. Check the SP3232 Driving Chip and related Circuit on
INTERFACE B'D.
Y
1. Check the connection of the RS-232C and Other side.
2. Check the I/F Cable whether it is open or short.
3. Check whether Signal is affected by the Cable Noise.
1. Check the connection of the H/W handshaking Line and Other
side
N
2. Check the I/F Cable whether it is open or short.
3. Confirm the H/W handshaking Protocol.
8 Troubleshooting