Parameters
A1S1 HL........................................................................................ Alarm 1, Setpoint 1 State
A1S1 VAL................................................................................................Alarm 1, Setpoint 1
A1S1TYPE .....................................................................................Alarm 1, Setpoint 1 Type
A1S2 HL........................................................................................ Alarm 1, Setpoint 2 State
A1S2 VAL................................................................................................Alarm 1, Setpoint 2
A1S2TYPE .....................................................................................Alarm 1, Setpoint 2 Type
A2S1 HL........................................................................................ Alarm 2, Setpoint 1 State
A2S1 VAL................................................................................................Alarm 2, Setpoint 1
A2S1TYPE ..............................................................................................Alarm 2, Setpoint 1
A2S2 HL........................................................................................ Alarm 2, Setpoint 2 State
A2S2 VAL................................................................................................Alarm 2, Setpoint 2
A2S2TYPE .....................................................................................Alarm 2, Setpoint 2 Type
AL HYST .................................................................................................... Alarm Hysteresis
BAUD ................................................................................................................... Baud Rate
BIAS IN1 ............................................................................................................ Input 1 Bias
CAL TEST ...........................................................................................Calibration test failure
Com ADDR ...................................................................... Communications Station Address
ComSTATE ............................................................................Communications Option State
CONFTEST.................................................................................... Configuration test failure
DUPLEX.................................................................................................... Duplex Operation
E E FAIL................................................................... Unable to write to non-volatile memory
EMSSIV................................................................................................................. Emissivity
EXT RSET............................................................................ External Reset (Digital Input 1)
FACT CRC ........................................................Factory Calibration Cyclic Redundancy test
FAILSAFE ............................................................................................ Controller in Failsafe
FILTER 1........................................................................................................... Input 1 Filter
IN1 HI ........................................................................................... Input 1 High Range Value
IN1 LO..........................................................................................Input 1 Low Range Value
IN1 TYPE .......................................................................................... Input 1 Actuation Type
INP1 RNG ............................................................................................Input 1 Out of Range
INP1FAIL...................................................... Two consecutive failures of Input 1 integration
LO or HI................................................................................................ Type of Limit Control
LOOPBACK ................................................................................................Local Loop Back
PARITY ........................................................................................................................ Parity
POWER UP.................................................................................................. Power-up Logic
PV LIMIT .................................................................................................... PV Out of Range
PWR FREQ....................................................................................... Power Line Frequency
RAM TEST .................................................................................................... RAM test failed
SHEDTIME...........................................................................................................Shed Time
SP HILIM................................................................................................. High Setpoint Limit
SP LOLIM................................................................................................. Low Setpoint Limit
UNITS ................................................................................................. Communication Units
XMITTER .................................................................................Transmitter Characterization