Generic Wiring - Interface Module (2-Channel Edm, Manual Reset) - Banner LS2e30-300Q8 Instruction Manual

Ez-screen type 2 light screen
Table of Contents

Advertisement

®
EZ-SCREEN
Type 2 Light Screen
4.5.3 Generic Wiring — Interface Module (2-Channel EDM, Manual Reset)
Receiver
8-pin male Euro-style
face view
*
NOTE:
Pins 2 and 3 are not connected, or are connected in parallel to the same color wire from the
emitter cordset and properly terminated.
Installation of transient (arc) suppressors across the coils of MPCE1 and MPC2 is recommended.
See
Single-Ended (Machine Interface) Cordsets
Other interfacing modules and solutions are available, see
WARNING: Use of Transient Suppressors
If transient suppressors are used, they MUST be installed across the coils of the machine control
elements. NEVER install suppressors directly across the contacts of the IM-T-..A Module. It is possible
for suppressors to fail as a short circuit. If installed directly across the contacts of the IM-T-..A Module,
a short-circuit suppressor creates an unsafe condition.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Bn (Pin #1)
+24V dc
Gn/Ye (#7)
Ground
Bu (#6)
0V dc
Bk (#5)
OSSD 1
Wh (#4)
OSSD 2
Reset/
Vi (#8)
Test
Or (#3)
n.c.
Or/Bk (#2)
n.c.
Figure 20. Generic Wiring — Interface Module (2-Channel EDM, Manual Reset)
+24V dc
IM-T-9A**
S3
S1
K2
K1
S4
S2
N.C.
Y3
Y4
Y1
Y2
13
14
23
24
Machine
Control
33
34
on page 48 for available cordset information
Accessories
on page 47.
0V dc
MPCE Monitoring
MPCE
1
*
MPCE
2
*

Hide quick links:

Advertisement

Table of Contents
loading