5
Group/
Category/
Description
Type/
Description
28-41-x-0
Channel Diagnosis
Disappears
PROFINET Alarm
received.
28-42-x-y
Channel Diagnosis
Appears PROFINET
Alarm received
(Alarm contains
Extended Channel
data).
28-43-x-y
Channel Diagnosis
Disappears
PROFINET Alarm
received (Alarm
contains Extended
Channel data).
28-44-x-y
Channel Diagnosis
Appears PROFINET
Alarm received
(Alarm contains
Qualified Channel
data).
28-45-x-y
Channel Diagnosis
Disappears
PROFINET Alarm
received (Alarm
contains Qualified
Channel data).
28-46-0-0
Diagnosis Appears
PROFINET Alarm
received (Alarm
contains only
Maintenance status).
28-47-0-0
Diagnosis Disappears
PROFINET Alarm
received (Alarm
contains only
Maintenance status).
28-48-0-0
Diagnosis Appears
PROFINET Alarm
received.
PACSystems* RX3i PROFINET Controller Manual – December 2011
5-22
Cause
A PROFINET Alarm has been
received indicating that a
Channel-level diagnostic
condition has been resolved on
the PROFINET device.
A PROFINET Alarm has been
received indicating that a
Channel-level diagnostic
condition has occurred on the
PROFINET device.
A PROFINET Alarm has been
received indicating that a
Channel-level diagnostic
condition has been resolved on
the PROFINET device.
A PROFINET Alarm has been
received indicating that a
Channel-level diagnostic
condition has occurred on the
PROFINET device.
A PROFINET Alarm has been
received indicating that a
Channel-level diagnostic
condition has been resolved on
the PROFINET device.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
detected on the PROFINET
device.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
resolved on the PROFINET
device and maintenance is no
longer required.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
detected on the PROFINET
device.
Recommended
Correction
None.
Note: Alarm details are provided in the
Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are provided in the
Fault Extra Data.
For complex analog modules, the
reference address displayed in the fault
identifies faults in all channels using the
discrete status data of the module's first
channel. If the fault is on channel 1, the
reference address is bit 1 of the channel
1 status data; if the fault is on channel 2,
the reference address is bit 2 of the
channel 1 status data, etc.
None.
Note: Alarm details are provided in the
Fault Extra Data.
Consult Device manufacturer
documentation.
Note: Alarm details are provided in the
Fault Extra Data.
None.
Note: Alarm details are provided in the
Fault Extra Data.
Consult Device manufacturer
documentation.
Note: Alarm details are provided in the
Fault Extra Data.
None.
Note: Alarm details are provided in the
Fault Extra Data.
Consult Device manufacturer
documentation.
Note: Alarm details are provided in the
Fault Extra Data.