DK-45 Kullanım Kılavuzu
10.2.5. COMPRESSOR PARAMETERS
ICON and No:
DESCRIPTION
PRESS. CONTROL :
Pressure sensor type
E.01
PRESS.TOP RANGE :
Pressure upper display
limit
E.02
HIGH PRES.ALARM :
High pressure alarm limit
E.03
STOP PRESSURE :
E.04
START PRESSURE :
E.05
PRES.SNSR.OFSET :
Pressure sensor offset
adjustment
E.06
TEMP. TOP RANGE :
Temperature display
upper limit
E.07
HIGH TEMP.ALARM :
High outlet temperature
alarm limit
E.08
HIGH TEMP.WARNG :
High outlet temperature
warning limit
E.09
LOW TEMP. ALARM :
Low outlet temperature
alarm limit
E.10
TEMP. OFFSET :
Temperature sensor
offset adjustment
E.11
ADJUSTMENT LIMITS
0: Analog sensor connected
1: Pressure switch connected
If this parameter is set to 1 then parameters
E.02 ... E.06 will not be visible.
1.7... 99.9
(E.02-0.5) ... (E.04+0.2)
(E.03-0.2) ... (E.05+0.2)
0.5 ... (E.04-0.2)
-2.0 ... +2.0
(E.08+2) ... 130
(E.09+2) ... (E.07-2)
(E.10+2) ... (E.08-2)
-10 ... (E.09-2)
-10 ... +10
- 41 -
V1.0 (22.09.2016)
Factory
Set
0
15.0 bar
8.5 bar
7.4 bar
6.5 bar
0.0 bar
130 °C
108 °C
103 °C
0 °C
0 °C
Need help?