DIMENSIONS

A
4 25 in (107 9 mm)
TOOUBLESHOOTING GUIDE
Issue
No LCD display
No rate or total
displayed
Flow rate display
interprets reading
constantly
Flow rate indicator
bounces
PAOT NUMBEOING
November 2017
A
B
4 25 in (107 9 mm)
• Check battery voltage Should be 1 5V DC Replace if low or bad
• Check connection from meter pickup to display input terminals
• Check turbine meter rotor for debris Rotor should spin freely
• Check programming of flow monitor
• This is usually an indication of external noise Keep all AC wires separate from DC wires
• Check for large motors close to the meter pickup
• Check for radio antenna in close proximity
• Try disconnecting the pickup from the monitor pig tail This should stop the noise
• This usually indicates a weak signal Replace pickup and/or check all connections
• Check K-factor
B 28 S X P - X X
Program Level
S - Simplified
Power Option
B - Battery
L - Loop
C
B
C
0 75 in (19 0 mm)
Oemedy
Units of Measure
AB - Gallons
ED - Barrels
HB - Liters
ID
- Cubic Meters
Mounting Style
P - Panel Mount
DSY-PM-00278-EN-04
D
E
D
2 50 in (63 5 mm)
4 54 in (115 3 mm)