APPLICATION

The Badger Meter BadgerTouch® Pit Module with Twist Tight®
connector for connectivity with an E-Series® Ultrasonic Meter
or Badger Meter High Resolution Encoder (HR-E®) is a complete
electronically encoded close-proximity automated meter reading
system, specifically designed for pit meter installations. This
system can be used with currently available E-Series Ultrasonic
3 and 4 inch meters, and HR-E encoders with all Recordall® Disc,
Turbo, Compound, Combo, and Fire Series meters and assemblies.
The Pit Module is designed to fit pit lid configurations up to
2 inches thick.

INSTALLATION

Unpacking

Carefully remove the BadgerTouch Pit Module from the shipping
carton and inspect the assembly for any damage.

Location

To ensure proper operation of the BadgerTouch meter reading
system, the BadgerTouch Pit Module should be mounted through
a predrilled hole in the pit lid. Minimum hole diameter required is
1-3/4 inch. The Pit Module contains electronic circuitry that is totally
encapsulated to enhance reliable performance in most locations,
under most conditions.

Pit Module Installation

1. Remove the locking nut and the coil assembly from the Pit
Module "mushroom" holder.
To remove the coil assembly, squeeze the tabs at the bottom of
the coil assembly, turn to unlock and pull the assembly out of
the holder.
2. From the outside of the pit lid, insert the Pit Module holder
through the lid.
3. Screw the locking nut (large diameter side up) onto the
threaded tube of the holder until the locking nut fits snugly
against the underside of the pit lid. See
4. Insert the coil assembly, which is connected to the lead wire,
into the Pit Module holder, until it is fully seated in the holder.
Turn the coil assembly until it locks into place.
5. Coil up any excess wire inside the pit and tie the cable to avoid
any damage.
BTA-UM-00234-EN-06 (January 2020)
BadgerTouch®
Automated Meter Reading System Pit Module
Model ESERIESBT and HREBT
Figure
1.
BadgerTouch
Pit Module
3.96 in. (101 mm)
Pit lid
1.75 in.
diameter
hole
2 in. max.
3.30 in. (84 mm)
Locking nut
Black housing
Twist Tight connector
Figure 1: BadgerTouch Pit Module with Twist Tight connector and
E-Series Ultrasonic meter

TESTING

Once the BadgerTouch Pit Module is secured through the pit lid and
connected to the meter/encoder, the BadgerTouch system is ready
for operation. No specific testing is required at the meter location
regarding proper connections. Interrogation of each module will
facilitate proper coordination of meters, modules and account. Use
a VersaProbe® or other equivalent reading device for interrogation
of the installed BadgerTouch modules.

LICENSE REQUIREMENTS

This device complies with Part 15 of the FCC Rules. Operation of
this device is subject to the following conditions: (1) This device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation of the device. Any changes made by the user
not approved by Badger Meter can void the user's authority to
operate the equipment.
In accordance with FCC Regulations, "Code of Federal Regulations"
Title 47, Part 2, Subpart J, Section 1091, transmitters pass the
requirements pertaining to radiation exposure. However, to
avoid public exposure in excess of limits for general population
(uncontrolled exposure), a
20 centimeter
transmitter and the body of the user must be maintained during
operation.
No license is required by the utility to operate a BadgerTouch meter
reading system.
(continued on back)
Installation Manual
distance between the

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BadgerTouch ESERIESBT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Badger Meter BadgerTouch ESERIESBT

  • Page 1 Any changes made by the user 2. From the outside of the pit lid, insert the Pit Module holder not approved by Badger Meter can void the user’s authority to through the lid. operate the equipment.
  • Page 2 The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882...

This manual is also suitable for:

Badgertouch hrebt

Table of Contents