Badger Meter Blancett B2800XP User Manual

Badger Meter Blancett B2800XP User Manual

Explosion proof flow monitor advanced
Hide thumbs Also See for Blancett B2800XP:

Advertisement

Quick Links

Flow Monitor
B2800XP Explosion Proof Flow Monitor Advanced
User Manual
DSY-PM-00279-EN-03 (March 2017)

Advertisement

Table of Contents
loading

Summary of Contents for Badger Meter Blancett B2800XP

  • Page 1 Flow Monitor B2800XP Explosion Proof Flow Monitor Advanced User Manual DSY-PM-00279-EN-03 (March 2017)
  • Page 2: Table Of Contents

    Flow Monitor, B2800XP Explosion Proof Flow Monitor Advanced CONTENTS Scope of This Manual Unpacking and Inspection Safety Terminology and Symbols Considerations Introduction Explosion Proof Enclosure Installation Installation Kits Operating The Monitor Buttons Modes Programming Programming Mode Return to Run Mode Run Mode Additonal Scaling Parameters Flow 4 mA Setting...
  • Page 3: Scope Of This Manual

    Scope of This Manual SCOPE OF THIS MANUAL This manual is intended to help you get the B2800 flow monitor up and running quickly MPOOTANT Read this manual carefully before attempting any installation or operation. Keep the manual accessible for future reference. UNPACKING AND INSPECTION Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment...
  • Page 4: Introduction

    Introduction INTOODUCTION The B2800XP flow monitor is a state-of-the-art digital signal processing flow monitor designed to provide the user with exceptional flexibility at a very affordable price Though designed for use with Blancett flow meters, this display can be used with almost any flow meter producing a low amplitude AC output or contact closure signals The B2800XP flow monitor is capable of accepting a low level frequency input for calculating flow rate and total These calculations can then be displayed in the desired units of measurement The monitor’s large eight digit by 0 50 inch (12 7...
  • Page 5: Installation

    Installation INSTALLATION ELECTRICAL POWER MUST BE TURNED OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE. 1 EIH Instrument enclosures are furnished with 3/4 inch NPT offset through feed cast hubs for conduit entries (Use Cooper Crouse-Hinds RE21-SA to reduce to 1/2 inch hubs ) 2 Secure the enclosure to the conduit system If the enclosure has mounting feet, select a mounting location that will provide sufficient strength and rigidity to support the enclosure as well as the enclosed device and wiring SELECT A MOUNTING LOCATION SO THAT THE ENCLOSURE WILL NOT BE SUBJECTED TO IMPACT BY HEAVY OBJECTS.
  • Page 6: Installation Kits

    Installation Kits INSTALLATION KITS To facilitate installation of the explosion proof B2800XP monitor, two sizes of installation kits are available Hub Size Kit Number Meter Sizes 1/2 in NPT Hub B280-742 3/8 in , 1/2 in , 3/4 in with 1/2 in NPT End Fittings 1 in NPT Hub B280-737 All Sizes with 1 in NPT End Fittings and Larger...
  • Page 7: Operating The Monitor

    Operating The Monitor OPEOATING THE MONITOO The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode Both the RUN mode and the PROGRAM mode display screen enunciators confirm the state of the monitor A quick glance at the lower left corner of the LCD screen will confirm operating status Normal operation is in the RUN mode To access the PROGRAM mode, press MENU until the first programming screen is displayed After programming the display with the necessary information, turn on the lock out feature to prevent unauthorized access or changing the meter’s setup parameters...
  • Page 8: Programming

    Programming POOGOAMMING Each turbine flow meter is shipped with either a K-factor value or frequency data If frequency data is provided, the data must be converted to a K-factor before programming the monitor K-factor information, when supplied, can usually be found on the neck of the flow meter or stamped on the flow meter body The K-factor represents the number of pulses per unit of volume The K-factor will be needed to program the monitor readout Programming Mode...
  • Page 9 Programming Select Oate (Time) Interval At the RATE INT prompt, press ENTEO The monitor shows the current time interval If the current selection is correct, press ENTEO to advance to the next parameter To change to an alternate time interval, press UP or OIGHT to scroll to the correct time interval Press ENTEO to save and advance to the TOTL UNT parameter OTEE: If flow rate is the only measurement of interest, press OIGHT to advance to the KFAC UNT to complete the...
  • Page 10 Programming Meter Type At the METERTYP prompt, press ENTEO The current meter type displays If the current selection is correct, press ENTEO to advance to the next parameter To change the type, press UP or OIGHT Press ENTEO to save and advance to the next parameter If GAS is selected, the operating pressure (psig) and operating temperature (°...
  • Page 11: Return To Run Mode

    Programming Password The password setting restricts access to PROGRAM mode Initially, the password is set to all zeros and any user can modify the paramter settings To change the password, press ENTEO at the PASSWORD prompt The first digit flashes Press UP to increment the digit and OIGHT to advance to the next digit After entering all digits, press ENTEO to store the password and advance to RST PSWD The new password is now required to enter PROGRAM mode With this password set, any user is able to reset the stored totals on the monitor...
  • Page 12: Additonal Scaling Parameters

    Additonal Scaling Parameters ADDITONAL SCALING PAOAMETEOS Figure 5: 4…20 mA programming menu OTEE: The programming instructions in this section are only available for loop powered units Battery powered units do not include these programming parameters Flow 4 mA Setting Zero is the default flow rate at the 4 mA setting If the current selection is correct, press ENTEO to advance to the Flow 20 mA parameter To change the setting, press UP to increment the flashing digit and press OIGHT to move to the next digit Press ENTEO to save and advance to the Flow 20 mA parameter Flow 20 mA Setting...
  • Page 13: Additional Input Options

    Additional Input Options ADDITIONAL INPUT OPTIONS The B2800 flow monitor is capable of receiving magnetic pickup input or a contact closure input Since most Blancett flow meters utilize a magnetic pickup, the monitor is shipped configured for magnetic pickup input To change to a contact closure input, remove JP2 from the bottom two pins and jumper them to the top two pins See Figure 7 External...
  • Page 14: Maintenance

    Maintenance MAINTENANCE ALWAYS DISCONNECT PRIMARY POWER SOURCE BEFORE OPENING ENCLOSURE FOR INSPECTION OR SERVICE. 1 Frequent inspection should be made A schedule for maintenance checks should be determined by the environment and frequency of use It is recommended that it should be inspected at least once a year 2 Perform visual, electrical and mechanical checks on all components on a regular basis a Visually check for undue heating evidenced by discoloration of wires or other components, damaged or worn parts, or leakage evidenced by water or corrosion in the interior...
  • Page 15: Pulse Output Signals For Linear Processes

    Additional Scaling Information Pulse Output Signals for Linear Processes Pulse output signals are related to flow rate by a constant, usually referred to as the K-factor The K-factor is reported as the number of accumulated pulses that represents a particular volume, such as gallon or liter K-factors are indicated in pulses per unit volume or counts per unit volume An example of a K-factor, normally supplied by the manufacturer, might be 2000 counts per gallon The K-factor is correlated to flow through a simple mathematical relationship: Frequency = K-factor ×...
  • Page 16: Troubleshooting Guide

    Troubleshooting Guide TOOUBLESHOOTING GUIDE Issue Oemedy • Battery Powered Version: Check battery voltage Should be 1 5V DC Replace if low or bad No LCD display • Loop Powered Version: Check for current flow in the loop Check polarity of the current loop connections for proper orientation •...
  • Page 17: Specifications

    Specifications SPECIFICATIONS Power Supply Options Battery Powered One D size, 1 5V alkaline battery Loop Powered 4…20 mA loop power Power Consumption Battery Powered Less than 1 mA @ 1 5V DC Loop Powered 25 mA (maximum) Alphanumeric Oate and Total Display Eight digit, 0 5 inch high numeric display Eight character, 0 25 inch high alphanumeric display Pulsed Output Signal...
  • Page 18: Dimensions

    Dimensions DIMENSIONS ¾ NPT MENU ENTER 5 1 in 5 25 in 2 6 in 5/16 in 4 51 in (19 31 mm) (19 87 mm) (9 84 mm) (1 19 mm) (17 07 mm) PAOT NUMBEO INFOOMATION B 28 A X X - X X Units of Measure Program Level AB - Gallons...
  • Page 19: Replacement Parts

    INTENTIONAL BLANK PAGE March 2017 DSY-PM-00279-EN-03 Page 19...
  • Page 20 The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul.