B2800 Flow Monitor – Simplified
Programming Manual
DSY-PM-00276-EN-01 (November 2013)

Advertisement

Table of Contents
loading

Summary of Contents for Badger Meter Blancett B2800

  • Page 1 Flow Monitor B2800 Flow Monitor – Simplified Programming Manual DSY-PM-00276-EN-01 (November 2013)
  • Page 2 Flow Monitor, B2800 Flow Monitor – Simplified Page ii November 2013...
  • Page 3: Table Of Contents

    Programming Manual CONTENTS INTRODUCTION SPECIFICATIONS OPERATING THE MONITOR BASIC PROGRAMMING MODE PROGRAMMING USING PULSE OUTPUT TURBINE FLOW METERS BATTERY REPLACEMENT ADDITIONAL INPUT OPTIONS TROUBLESHOOTING GUIDE DEFAULT K FACTOR VALUES ADDITIONAL SCALING PARAMETERS B2800 Simplified 4-20 mA Programming Instructions PART NUMBERING INFORMATION REPLACEMENT PARTS November 2013 Page iii...
  • Page 4 Flow Monitor, B2800 Flow Monitor – Simplified Page iv November 2013...
  • Page 5: Introduction

    Programming Manual INTRODUCTION The B2800 Flow monitor is a state-of-the-art digital signal processing flow monitor, designed to provide the user with exceptional flexibility at a very affordable price Though designed for use with Blancett flow meters, this display can be used with almost any flow meter producing a low amplitude AC output or contact closure signal(s) This flow monitor is capable of accepting a low level frequency input for calculating flow rate and total These calculations can then be displayed in the desired units of measurement All B2800 Flow monitors come pre-calibrated from the factory,...
  • Page 6: Specifications

    Flow Monitor, B2800 Flow Monitor – Simplified SPECIFICATIONS Power Supply Options Battery Powered One D size, 1 5V alkaline battery Loop Powered Optional 4-20 mA loop power Alphanumeric Rate and Total Display Eight digit, 0 75 inch high numeric display Eight character, 0 38 inch high alphanumeric display Fixed or toggle modes of operation for flow rate and totalizer display Accuracy...
  • Page 7: Basic Programming Mode

    Programming Manual BASIC PROGRAMMING Keys MENU – Switches to PROGRAM mode UP Arrow – Scrolls forward through the parameter choices and increments numeric variables RIGHT Arrow – Scrolls backward through the parameter choices and moves the active digit to the right ENTER –...
  • Page 8 Flow Monitor, B2800 Flow Monitor – Simplified Select Meter Size At the METER prompt, press the UP or RIGHT arrows to select the bore size of your meter Press ENTER to save meter size choice and advance to the K factor units selection OTEE: The meter connection size and the bore size are different For example, many of the one inch NPT turbines have bore sizes that range from 3⁄8 inch up to 1 inch Be sure to use the correct bore size or the meter will report incorrect flows...
  • Page 9: Battery Replacement

    Programming Manual Password Password protection prevents unauthorized users from changing programming information Initially, the password is set to all zeros To change the password, simply enter any four digit code using the arrow keys as previously described to enter the password value Pressing ENTER once will store the password and take you back to the RST PSWD screen OTEE: This password will allow the operator to manually reset totals...
  • Page 10 Flow Monitor, B2800 Flow Monitor – Simplified Pulse Input Card 30V DC (Max) 20 mS Pulse + Pulse In - Pulse In Magnetic Pickup Analog Input Card - 4-20 mA 10…30V DC (Loop Supply Voltage - 5) - Common 0.02 Figure 3: Wiring diagram Loop Powered Battery Powered...
  • Page 11: Troubleshooting Guide

    Programming Manual TROUBLESHOOTING GUIDE Trouble Remedy • Check battery voltage Should be 1 5V DC Replace if low or bad No LCD Display • Check connection from meter pickup to display input terminals No Rate or Total • Check turbine meter rotor for debris Rotor should spin freely Displayed •...
  • Page 12 Flow Monitor, B2800 Flow Monitor – Simplified Figure 5: Basic programming menu Page 12 November 2013...
  • Page 13: Additional Scaling Parameters

    Programming Manual ADDITIONAL SCALING PARAMETERS OTEE: The programming instructions below are only available for loop powered units Battery powered units will not see these programming choices B2800 Simplified 4-20 mA Programming Instructions FLOW 4 mA Setting When the loop powered option is ordered, the flow rate that corresponds to 4 mA must be set Zero is default flow rate for this setting If the current selection is correct, press ENTER once to advance to the next parameter If adjustment is required, use the RIGHT arrow to select the position of the number you wish to change Then use the UP arrow to increment the number Once you have completed this step, press ENTER to advance to the next parameter...
  • Page 14 Flow Monitor, B2800 Flow Monitor – Simplified Input Keypad Connector 1 2 3 4 5 Pulse Inuput Pulse Out 4-20 mA Freq. In 10…30V DC 1…5V DC Figure 6: Typical ammeter connection IO/SETUP PULSE OUTPUT Flow 4MA Flow 20MA 4MA OUT 20MA OUT 4-20 TEST PASSWORD...
  • Page 15 Programming Manual November 2013 Page 15...
  • Page 16: Part Numbering Information

    The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0 Czech Republic | Badger Meter Czech Republic s.r.o.