Badger Meter Blancett B3100 Series User Manual
Badger Meter Blancett B3100 Series User Manual

Badger Meter Blancett B3100 Series User Manual

Flow monitor data logging
Hide thumbs Also See for Blancett B3100 Series:

Advertisement

Quick Links

Flow Monitor
B3100 Series Data Logging
User Manual
DSY-UM-02260-EN-01 (April 2017)

Advertisement

Table of Contents
loading

Summary of Contents for Badger Meter Blancett B3100 Series

  • Page 1 Flow Monitor B3100 Series Data Logging User Manual DSY-UM-02260-EN-01 (April 2017)
  • Page 2 NOTICE This User Manual is meant as a quick reference document and is an addendum to the documentation set that came with the B3100. This User Manual assumes that the B3100 is installed in the field. DSY-UM-02260-EN-01 (April 2017)
  • Page 3 Blancett B3100 Flow Monitor, Datalogging Page 3 DSY-UM-02260-EN-01 (April 2017)
  • Page 4: Table Of Contents

    Blancett B3100 Flow Monitor, Datalogging Page 4 Table of content GENERAL INFORMATION ....................5 About this User Manual ......................5 1.1.1 Scope of the User Manual ........................5 TECHNICAL SPECIFICATION ....................6 Setup menu structure ......................6 Operational menu structure ....................6 Communication ........................6 Hardware requirements ......................7 Log data specifications ......................7 DESCRIPTION ........................7 Functional description ......................7...
  • Page 5: General Information

    Blancett B3100 Flow Monitor, Datalogging Page 5 1 General information The B3100 is certified for use in the specified hazardous area as specified. The allowed use of the B3100 is determined by the applicable certification authority and is specified on the certification label which is attached to the housing.
  • Page 6: Technical Specification

    Blancett B3100 Flow Monitor, Datalogging Page 6 2 Technical specification This chapter gives the technical specification of the data log function of the B3100, Flow Monitor. NOTICE The data log menu is accessed through the setup menu. As a result of different options installed the menu number can vary.
  • Page 7: Hardware Requirements

    Blancett B3100 Flow Monitor, Datalogging Page 7 2.4 Hardware requirements ESCRIPTION PECIFICATION Free disk space 10 MB Operation system Windows XP or higher Application 2 MB 2.5 Log data specifications ESCRIPTION PECIFICATION Interval log 1000 records Daily log, single 1 record per day with a maximum of 1000 records (1000 days) Daily log, dual 2 records per day with a maximum of 1000 records (500 days) Event log...
  • Page 8: The Daily Records

    Blancett B3100 Flow Monitor, Datalogging Page 8 3.2.2 The daily records The daily records are used to log the daily records, also known as contract hours (user defined). Each daily record has: • a sequence number; • a date/time stamp; •...
  • Page 9: The Event Records

    Blancett B3100 Flow Monitor, Datalogging Page 9 4.1.3 The event records This log is used to record the events. These events have a generic or a specific content (manufacturer defined). The B3100 makes one record every time an event occurs. When the maximum amount of records is made, the eldest record is overwritten by the newest record.
  • Page 10: Program The Daily Log

    Blancett B3100 Flow Monitor, Datalogging Page 10 5.2 Program the daily log ACTION RESULT EMARK • The SETUP indicator comes 1. Press the PROG button To enter the setup menu. for at least 7 seconds. on continuously. • The setup menu TOTAL shows.
  • Page 11: Program The Events Log

    Blancett B3100 Flow Monitor, Datalogging Page 11 ACTION RESULT EMARK 13. Press the ▲ and the • The selected time shows. Only the digit that blinks can ► button to change the be changed. Use the ► button to scroll between the digits. time.
  • Page 12: Read-Out The Log Data

    Blancett B3100 Flow Monitor, Datalogging Page 12 ACTION RESULT EMARK • The PROG indicator blinks 8. Press the PROG button If you wait too long, the momentarily. program mode goes off and continuously. • The first digit of the date changes are not saved, this is normal behavior blinks.
  • Page 13: Read-Out The Daily Log

    Blancett B3100 Flow Monitor, Datalogging Page 13 ACTION RESULT EMARK • The LOG indicator goes off. 8. Press and hold the • The operator menu shows. PROG button for at least 3 seconds. 6.2 .Read-out the daily log NOTICE This procedure assumes that the B3100 shows the operator menu. NOTICE When the daily log is set to dual, there are two time stamps.
  • Page 14 Blancett B3100 Flow Monitor, Datalogging Page 14 ACTION RESULT EMARK • The RUN indicator stays on. 1. Press and hold the In the background, the B3100 ► button until the • The LOG indicator comes stays operational. DATALOG menu shows. 2.
  • Page 15: Job Close Up

    Blancett B3100 Flow Monitor, Datalogging Page 15 7 Job close up 1. Remove any USB connections. 2. Close the USB connection port in a Ex d safe manner. 3. Remove all tools, materials and equipment from the work area. 4. Make sure, the work area is clean. 5.
  • Page 16 The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul.

Table of Contents