Scope of This Manual SCOPE OF THIS MANUAL This manual is intended to help you install and operate the QuikSert turbine flow meter� MPORTANT Read this manual carefully before attempting any installation or operation. Keep the manual accessible for future reference. UNPACKING AND INSPECTION Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such as scratches, loose or broken parts, or...
Introduction INTRODUCTION The QuikSert Standard turbine flow meter was developed for liquid applications where accuracy and dependability are of concern to the operator� The stainless steel body incorporates a helical turbine with tungsten carbide shaft and bearings� It provides an efficient, long service life and a cost-effective solution for your measurement requirements�...
Installation INSTALLATION 1� Check the flow meter internally for foreign material and make sure the turbine rotor spins freely prior to installation� 2� Check fluid lines and clear any debris� 3� Install the flow meter with the flow arrow, etched on the exterior of the meter body, pointing in the direction of fluid flow�...
Page 6
Installation Display Flow Straightner (Optional) QuikSert Turbine Flow Meter Isolation Valve 10 Pipe Diameters 5 Pipe Diameters Minimum Minimum Figure 3: Meter installation without using a bypass line 7� Install all restrictions in the flow line that may cause the liquid to flash, downstream of the meter�...
Operational Startup OPERATIONAL STARTUP Follow these steps when installing and starting the meter� MAKE SURE THAT FLUID FLOW HAS BEEN SHUT OFF AND PRESSURE IN THE LINE RELEASED BEFORE ATTEMPTING TO INSTALL THE METER IN AN EXISTING SYSTEM. 1� Close the isolation valves and open the bypass valve after installing the meter� 2�...
Troubleshooting Guide TROUBLESHOOTING GUIDE Trouble Possible Cause Remedy Meter indicates higher than actual • Cavitation • Increase back pressure flow rate • Debris on rotor • Clean meter support • Build up of foreign • Clean meter material on meter bore •...
Part Number Information PART NUMBER INFORMATION Meter Bore Max. Pres- Part Flow Strainer Approx. K-Factor Size × Line Weight sure Drop Number* Connection Range Mesh pulses/US gal Size (in.) (psi) B131-038 3/8 × 1 — 18,000 — 3�75 B131-050 1/2 × 1 —...
Specifications SPECIFICATIONS Body 316 stainless steel Rotor CD4MCU stainless steel Materials of Bearings Tungsten carbide Construction Rotor Shaft Tungsten carbide Rotor Support — –150…350° F (–101…177° C) standard Operating Temperatures to 450° F (232° C) with high-temp pickup, consult factory for details Temperature The standard meter should not be subjected to temperatures above 350°...
Page 12
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq� Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul�...