LOC
PG
104 29 PARTITION 7, ACCOUNT CODE
105 29
PARTITION 7, FEATURE AND REPORTING SELECTION
Segment #1
1 =Quick Arm '
2 = Re-Exit '
3 = Auto Bypass '
4 = Silent Panic '
5 = Audible Panic '
6 = Auxiliary 1 '
7 = Auxiliary 2 '
8 = Multi Keypress Tamper '
106 29
PARTITION 7 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
107 29 PARTITION 8, ACCOUNT CODE
108 29
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
1 =Quick Arm '
2 = Re-Exit '
3 = Auto Bypass '
4 = Silent Panic '
5 = Audible Panic '
6 = Auxiliary 1 '
7 = Auxiliary 2 '
8 = Multi Keypress Tamper '
109 29
PARTITION 8 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
110 30 ZONE TYPE 1 ALARM EVENT CODE
111 30
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1
1 = Fire (enable for fire zone) '
2 = 24 Hour (enable for non-fire 24 hour zone) '
3 = Keyswitch zone '
4 = Follower (enable for burg zones that are instant during non-entry times) '
5 = Delay 1 zone (enable to follow Timer 1 Entry/Exit times) '
6 = Delay 2 zone (enable to follow Timer 2 Entry / Exit times) '
7 = Interior (Enable for auto bypass or stay arming) '
8 = Local Only (enable if zone is not to be reported) '
Segment #2
1 = Keypad audible on alarm '
2 = Yelping siren on alarm '
3 = Temporal siren on alarm '
4 = Chime '
5 = Bypassable '
6 = Group Shunt '
7 = Force armable '
8 = Entry Guard '
42
Technical Manuals Online! - http://www.tech-man.com
DESCRIPTION
DEFAULT
10-10-10-10-10-10
Segment #2
1 = LED Extinguish enable '
2 = Require user code for
bypassing zones '
3 = Bypass sounder alert '
4 = AC Power/Low Battery
sounder alert '
5 = Enable Bypass toggle '
6 = Enable Silent Auto Arm '
7 = Enable Automatic Instant '
8 = Reserved
10-10-10-10-10-10
Segment #2
1 = LED Extinguish enable '
2 = Require user code for
bypassing zones '
3 = Bypass sounder alert '
4 = AC Power/Low Battery
sounder alert '
5 = Enable Bypass toggle '
6 = Enable Silent Auto Arm '
7 = Enable Automatic Instant '
8 = Reserved
DATA
_ _ _ _ _ _
Segment #3
1 = Open/Close '
2 = Bypass '
3 = Restore '
4 = Trouble '
5 = Tamper '
6 = Cancel '
7 = Recent Closing '
8 = Exit Error '
0
___
0
___
0
___
0
___
_ _ _ _ _ _
Segment #3
1 = Open/Close '
2 = Bypass '
3 = Restore '
4 = Trouble '
5 = Tamper '
6 = Cancel '
7 = Recent Closing '
8 = Exit Error '
0
___
0
___
0
___
0
___
8
___