LOCATION 95 - ACCOUNT CODE FOR PARTITION 4
(6 segments, numerical data) The account code sent when partition 4 is reported is programmed in location 95. If
location 95 is left unprogrammed (all A10") then the account code corresponding to the Phone number dialed
will be used. If the account code is less than six digits, program a A10" in the segment immediately after the last digit of
the account code. If the account code is 6 digits long, program all 6 segments.
LOCATION 96 - PARTITION 4 FEATURE AND REPORTING SELECTIONS
(3 segments, feature selection data) Location 96 is used to enable certain features that can be accessed or are visible
to the user from the keypad of the system. In addition, certain communicator reports are enabled in this location. Each
of these features can be enabled by partition. This location contains 3 segments, with eight possible features per
segment. Refer to Location 23, Segments 1 - 3 on page 18 for the feature selections. If all segments are blank
(nothing enabled), the features for partition 1 will be used.
LOCATION 97 - PARTITION 4 ENTRY EXIT TIMERS
(4 segments, numerical data) Location 97 is used to enter in seconds the Entry and exit times. There are 2 separate
entry and exit times. Valid entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition
1 will be used.
Segment 1, Entry time 1:
Segment 2, Exit time 1:
Segment 3, Entry time 2:
Segment 4, Exit time 2:
LOCATION 98 - ACCOUNT CODE FOR PARTITION 5
(6 segments, numerical data) The account code sent when partition 5 is reported is programmed in location 98. If
location 98 is left unprogrammed (all A10" ) then the account code corresponding to the Phone number dialed
will be used. If the account code is less than six digits, program a A10" in the segment immediately after the last digit of
the account code. If the account code is 6 digits long, program all 6 segments.
LOCATION 99 - PARTITION 5 FEATURE AND REPORTING SELECTIONS
(3 segments, numerical data) Location 99 is used to enable certain features that can be accessed or are visible to the
user from the keypad of the system. In addition, certain communicator reports are enabled in this location. Each of
these features can be enabled by partition. This location contains 3 segments, with eight possible features per segment.
Refer to Location 23, Segments 1 - 3 on page 18 for the feature selections. If all segments are blank (nothing
enabled), the features for partition 1 will be used.
LOCATION 100 - PARTITION 5 ENTRY EXIT TIMERS
(4 segments, numerical data) Location 100 is used to enter in seconds the Entry and exit times. There are 2 separate
entry and exit times. Valid entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition
1 will be used.
Segment 1, Entry Time 1:
Segment 2, Exit Time 1:
Segment 3, Entry Time 2:
Segment 4, Exit Time 2:
LOCATION 101 - ACCOUNT CODE FOR PARTITION 6
(6 segments, numerical data) The account code sent when partition 6 is reported is programmed in location 101. If
location 101 is left unprogrammed (all A10" ) then the account code corresponding to the Phone number dialed
will be used. Program the account code is less than six digits, program a A10" in the segment immediately after the last
digit of the account code. If the account code is 6 digits long, program all 6 segments.
LOCATION 102 - PARTITION 6 FEATURE AND REPORTING SELECTIONS
(3 segments, feature selection data) Location 102 is used to enable certain features that can be accessed or are visible
to the user from the keypad of the system. In addition, certain communicator reports are enabled in this location. Each
of these features can be enabled by partition. This location contains 3 segments, with eight possible features per
segment. Refer to Location 23, Segments 1 - 3 on page 18 for the feature selections. If all segments are blank
(nothing enabled), the features for partition 1 will be used.
28
Technical Manuals Online! - http://www.tech-man.com
Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Exit time that will be used for all zones designated as Delay 1.
Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Exit time that will be used for all zones designated as Delay 2.
Entry time that will be used when a delay 1 zone type initiates an entry delay.
Exit time that will be used for all zones designated as delay 1.
Entry time that will be used when a delay 2 zone type initiates an entry delay.
Exit time that will be used for all zones designated as delay 2.