Segment 2
1 = On enables the "Go To Program Code" for Partition #1.
2 = On enables the "Go To Program Code" for Partition #2.
3 = On enables the "Go To Program Code" for Partition #3.
4 = On enables the "Go To Program Code" for Partition #4.
5 = On enables the "Go To Program Code" for Partition #5.
6 = On enables the "Go To Program Code" for Partition #6.
7 = On enables the "Go To Program Code" for Partition #7.
8 = On enables the "Go To Program Code" for Partition #8.
LOCATION 44 - DURESS CODE
(6 segments, numerical data) Location 44 contains the
6-digit code option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not
enabled in location 41, the last 2 digits will be ignored. If programmed, the duress code will work for all partitions.
LOCATION 45 - OUTPUTS 1-4 PARTITION SELECTION
(4 segments, feature selection data) Location 45 is used to select which partition(s) the events must occur in before the
output will activate. Location 45 has 4 segments. Segments 1 and 2 correspond to relays/outputs 1 and 2, while
segments 3 and 4 correspond to auxiliary outputs 3 and 4.
Segment 1
(Relay / Output 1)
1= Partition #1
2= Partition #2
3= Partition #3
4= Partition #4
5= Partition #5
6= Partition #6
7= Partition #7
8= Partition #8
LOCATION 46 – OUTPUTS 1-4 SPECIAL TIMING
(4 segments, feature selection data) Location 46 contains special timing feature activation for outputs 1 - 4. Segments
1 and 2 correspond to relays/outputs 1 and 2, while segments 3 and 4 correspond to auxiliary outputs 3 and 4.
Segments 1 - 4
1 = On if output should be timed in minutes; Off if timed in seconds.
2 = On if output should latch; Off if output should be timed.
3 = On if output should stop timing upon code entry; Off if the output should continue to time upon code entry.
4 = On if output should only activate between the closing and opening time in loc. 52 & 53.
5 = On if output should only activate between the opening and closing time in loc. 52 & 53.
6 = On if output should be inverted (0 volts going to 12 volts when activated).
7 = Reserved.
8 = Reserved.
LOCATION 47 – RELAY / OUTPUT #1, EVENT AND TIME
(2 segments, numerical data)
Segment 1:
Use Table 9-2 on page 25 to select the event that will activate output relay/output 1.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 1,
Location 46). Programming a "0" makes the relay/output follow the event.
LOCATION 48 – RELAY / OUTPUT #2, EVENT AND TIME
(2 segments, numerical data)
Segment 1:
Use Table 9-2 on page 25 to select the event that will activate output relay/output 2.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 2,
Location 46). Programming a "0" makes the relay/output follow the event.
LOCATION 49- OUTPUT #3, EVENT AND TIME
(2 segments, numerical data)
Segment 1:
Use Table 9-2on page 25 to select the event that will activate output 3.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 3,
Location 46). Programming a "0" makes the output follow the event.
24
Technical Manuals Online! - http://www.tech-man.com
Duress
Segment 2
(Relay / Output 2)
1= Partition #1
2= Partition #2
3= Partition #3
4= Partition #4
5= Partition #5
6= Partition #6
7= Partition #7
8= Partition #8
code. This Location contains either 4 or 6 digits. If the
Segment 3
(Aux. Output 3)
1= Partition #1
2= Partition #2
3= Partition #3
4= Partition #4
5= Partition #5
6= Partition #6
7= Partition #7
8= Partition #8
Segment 4
(Aux. Output 4)
1= Partition #1
2= Partition #2
3= Partition #3
4= Partition #4
5= Partition #5
6= Partition #6
7= Partition #7
8= Partition #8