LOC
PG
Segment #5
1 = Lost Clock "Service Required" message enable '
2 = Reserved
3 = Disable on-board eight zones '
4 = Enables two trips on the same cross-zone to activate the alarm '
5 = Disables bypass reports for force armed zones '
6 = Silent exit '
7 = Clock uses internal crystal '
8 = Disable Temporal Siren on Fire (Do not disable on UL listed systems) '
38
22 SWINGER SHUTDOWN COUNT
39
22
KEYPAD SOUNDER CONTROL
Segment #1
1 = Keypad sounds for Telephone Line Cut when in the Armed state '
2 = Keypad sounds for Telephone Line Cut when in the Disarmed state '
3 = Keypad sounds upon AC Power Failure '
4 = Keypad sounds upon Low Battery Detection '
5 = Keypad sounds during
6 = Keypad sounds for Tamper Alarm '
7 = Reserved
8 = Keypad sounds for expander trouble (required for UL) '
40
22
SYSTEM TIMERS
Segment #1 Dynamic Battery Test duration (0-255
minutes)
Segment #2 AC Failure report delay (0-255 hours)
Segment #3 Power Up Delay (0-60 seconds)
Segment #4 Siren Time (1-255 minutes)
Segment #5 Telephone Line Cut delay (10-175 seconds)
Segment #6
Segment #7 Chime Time in 50 mS increments (0-255)
Segment #8 Dialer delay ( 0-255 seconds)
Segment #9 Fire Alarm Verification Time (120-240 sec.)
Segment #10 Reserved
41
23
SPECIAL FEATURES
Segment #1
1 - 2 = Reserved
3 = Enable
4 = Enable
5 - 8 = Reserved
42
23 GO TO PROGRAM CODE
43
23
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment #1
1 = Reserved
2 = Enables "Go To Program Code" as an arm only code '
3 = Enables "Go To Program Code" as an arm only after closing '
4 = Enables "Go To Program Code" as a master arm/disarm code (can change user codes) '
5 = Enables "Go To Program Code" as an arm/disarm code '
6 = Enables "Go To Program Code" to bypass zones '
7 = Enables "Go To Program Code" opening and closing reports '
8 = Reserved
Segment #2
1 = Enables "Go To Program Code" for partition #1 '
2 = Enables "Go To Program Code" for partition #2 '
3 = Enables "Go To Program Code" for partition #3 '
4 = Enables "Go To Program Code" for partition #4 '
5 = Enables "Go To Program Code" for partition #5 '
6 = Enables "Go To Program Code" for partition #6 '
7 = Enables "Go To Program Code" for partition #7 '
8 = Enables "Go To Program Code" for partition #8 '
44
24
DURESS CODE
38
Technical Manuals Online! - http://www.tech-man.com
DESCRIPTION
Cross Zone
Cross Zone
Time (0-255 minutes)
'
Auto Cancel / Abort
'
Walk-Test Mode
DEFAULT
0
Trip Time '
9-7-1-3-0-0
15-15-15-15-15-15
DATA
_
0
_____
6
_____
0
_____
8
_____
30
_____
5
_____
3
_____
0
_____
0
_____
_ _ _ _ _ _
___ ___ ___ ___ ___ ___
NX-8 Commercial Fire

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for GE Interlogix NX-8

Table of Contents