installation
|
22

AC ADAPTOR INSTALLATION

AC ADAPTOR INSTALLATION
A hard wire kit is available for this unit as an option (see hard wire kit instructions), to hard wire this appliance, a qualified electrician must
remove the cord connection, and wire the appliance directly to the household wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
WARNING!
USE ONLY A GROUND FAULT INTERRUPTER (GFI) PROTECTED CIRCUIT WITH THIS OUTDOOR GAS APPLIANCE .
ENSURE THAT ALL POWER SOURCES HAVE BEEN SHUT OFF PRIOR TO BEGINNING ANY ELECTRICAL WORK.
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER.
CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELEC-
TRICAL CIRCUIT.
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
INCORRECT WIRING WILL DAMAGE CONTROLS AND IS NOT COVERED BY THE WARRANTY.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES. IN
THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT
NATIONAL ELECTRIC CODE ANSI / NFPA NO. 70 IN THE UNITED STATES.
Important: Electrical box must be located within 10 feet of the burner(s) as the AC adaptor is 10 feet long and will not reach the
DC supply wire connection if any farther.
The 4 AA batteries do not need to be installed if using the AC adaptor. The batteries would only be required in the event that
120V power is lost.
1. Remove the valve cover plate on side of unit to expose the DC supply
tooltip
wire by removing 6 screws
NOTE: The valve cover plate should be removed prior to being installed
into the framing kit or framing in general for ease of access to these 6
screws. This would also apply when reinstalling the valve cover plate.
2. Locate the 'DC supply' wire on the wiring harness,the wire will
be clearly marked.
AC adaptor
22 |
Regency Horizon® HZO42 Gas Fireplace
Valve cover plate
DC supply wire from wiring harness
OUTDOOR SERIES
3. Run the AC adaptor wire from the recently installed electrical
box, to the back of the unit end, connect the AC Adaptor with
the DC supply wire in the previous step.
4. Attach the AC adaptor to the DC supply wire. Secure wire using a
strain relief ( see enclosed picture) Reinstall the valve cover plate
(reverse Step 2).
5. Plug the AC adaptor into a grounded fault interrupter (GFI)
protected circuit.
6. Turn on gas and electrical supply and test unit.