Regency Fireplace Products HZI390E Owners & Installation Manual

Regency Fireplace Products HZI390E Owners & Installation Manual

Hide thumbs Also See for HZI390E:
Table of Contents

Advertisement

Quick Links

L390E / HZI390E Gas Insert
MODELS: L390E-NG1 / L390EB-NG1 Natural Gas
HZI390E-NG1 / HZI390EB-NG1 Natural Gas
WarninG:
improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. refer to
this manual. for assistance or additional information consult
an authorized installer, service agency or the gas supplier.
for Your safetY
do not store or use gasoline or other flammable vapours and
liquids in the vicinity of this or any other appliance.
installation and service must be performed by an authorized
installer, service agency or the gas supplier.
Tested by:
919-090
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
fpi fireplace products international ltd. 6988 Venture st., delta, Bc canada, V4G 1H4
L390E-LP1 / L390EB-LP1 Propane
HZI390E-LP1 / HZI390EB-LP1 Propane
for Your safetY
What to do if you smell gas:
do not try to light any appliance
do not touch any electrical switch:
do not use any phone in your
building.
immediately call your gas supplier
from a neighbour's phone. follow
the gas supplier's instructions.
if you
supplier, call the fire department.
owners &
installation Manual
www.regency-fire.com
cannot reach your gas
03/14/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HZI390E and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products HZI390E

  • Page 1 & L390E / HZI390E Gas Insert installation Manual www.regency-fire.com MODELS: L390E-NG1 / L390EB-NG1 Natural Gas L390E-LP1 / L390EB-LP1 Propane HZI390E-NG1 / HZI390EB-NG1 Natural Gas HZI390E-LP1 / HZI390EB-LP1 Propane WarninG: for Your safetY improper installation, adjustment, alteration, service or What to do if you smell gas: maintenance can cause injury or property damage.
  • Page 2 The Regency Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The models L390E / HZI390E of this series have been approved by Warnock Hersey for both safety and efficiency.
  • Page 3: Unit Dimensions

    (76mm) 25-3/4” (654mm) 17” 19-1/2” 14-3/4” 20” (432mm) (495mm) (375mm) (508mm) 24-1/8” 15-1/2” (613mm) (399mm) 39-7/8” (1013mm) 39-15/16” (1014mm) 35-15/16” (911mm) 38-1/8” (968mm) 17-1/4” (438mm) Dimensions w/Full Screen Doors Dimensions w/4 sided Faceplate L390E / HZI390E Direct Vent Gas Insert...
  • Page 4: Table Of Contents

    Main Assembly ............50 Low profile faceplate ...........52 Fan installation / removal..........19 Wiring Diagram ............21 Proflame Remote system gtm (L390E / HZI390E) ..21 AC power adaptor installation (for surefire systems) ...22 WArrAnTy Proflame remote system GTMF with fan .....23 Fan Wiring Diagram ............24 Warranty ..............55...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. L390E / HZI390E Direct Vent Gas Insert...
  • Page 6 This is a copy of the labels that accompany each HZI390E Gas Insert. NOTE: regency units are constantly being improved. check the We have printed a copy of the contents here for your review. label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 7: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. L390E / HZI390E Direct Vent Gas Insert...
  • Page 8: Installation

    INSTRuCTIONS ance. toddlers, YounG cHildren and otHers MaY Be susceptiBle The L390E / HZI390E Gas Inserts must be installed to accidental contact Burns. a in accordance with these instructions. Carefully read pHYsical Barriers is recoMMend- all the instructions in this manual first.
  • Page 9: Important Message

    FOr yOur sAFETy 4) See general construction and assembly The L390E / HZI390E Gas Inserts have been instructions. This appliance may only be tested and approved to be vented into any installed in a vented, noncombustible This appliance requires air for proper combustion.
  • Page 10: Before You Start Installation Checklist

    Clocking the appliance to ensure the correct firing rate. b) Adjusting the primary air, if required, to ensure that the flame does not carbon. See "Gas Insert Aeration System" section. c) Ensuring that the appliance is venting correctly. L390E / HZI390E Direct Vent Gas Insert...
  • Page 11: Minimum Clearances To Combustibles

    Do not use the hearth as a seat or shelf. at a lower height if the framing is made of metal studs covered with a noncombustible board. L390E / HZI390E Direct Vent Gas Insert...
  • Page 12: Gas Connection

    35' (10.7m). See chart for minimum distances from roof. Periodically check that the vent is unrestricted. Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. L390E / HZI390E Direct Vent Gas Insert...
  • Page 13: Flue / Vent Installation

    Flue Connector Plate Gasket WarninG: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. L390E / HZI390E Direct Vent Gas Insert...
  • Page 14: Leveling Leg Adjustment

    LEVELIng LEg AdjusTMEnT The L390E / HZI390E inserts are equipped with 4 levelling legs that are accessible while the appliance is in its final installation position. The unit can be adjusted up to 2" (51mm). The faceplate must not be installed to do this adjustment, if installed, remove faceplate.
  • Page 15: Air Shutter Adjustment

    The L390E / HZI390E is equipped with an air shutter that is accessible from outside the firebox and can be adjusted during operation.
  • Page 16: Conversion From Ng To Lp

    FrOM ng TO Lp CONVERSION FROM NG TO LP L390E-1/HZI390E-1 using SIT 885 NOVA Gas Valve L390E-1/HZI390E-1 using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION! WARNING This conversion kit shall be installed by a qualifi...
  • Page 17 Verify both the correct fl ame and pilot appearance. 12) See Gas Pipe Pressure Testing in this manual. 13) Adjust aerations settings - see Air Shutter Adjustment section in this manual. L390E / HZI390E Direct Vent Gas Insert 919-093 11/28/11...
  • Page 18: High Elevation

    6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. L390E / HZI390E Direct Vent Gas Insert...
  • Page 19: Fan Installation / Removal

    Note: Instructions on installation are only required if fan was not installed 4) Install the thermodisc by sliding it into the bracket as shown below in with L390E/ L540E or HZI390E/HZI540E only. To access the side and Diagram 4. rear access panels both the gas and venting (see vent/fl ue installa- tion in this manual) will need to be disconnected for proper removal.
  • Page 20 This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Diagram 10 L390E / HZI390E Direct Vent Gas Insert 919-019a 03/06/12...
  • Page 21: Wiring Diagram

    This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. (do not cut the ground terminal off under any circumstances.) prOFLAME rEMOTE sysTEM gTM (L390E / HZI390E) Proflame System Configuration...
  • Page 22: Ac Power Adaptor Installation (For Surefire Systems)

    5) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: Ensure that wires do not touch the underside of the firebox (keep wires away from the heat as much as possible). FCM - COM L390E / HZI390E Direct Vent Gas Insert 08/15/2011 919-063...
  • Page 23: Proflame Remote System Gtmf With Fan

    Label all wires prior to disconnection Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. L390E / HZI390E Direct Vent Gas Insert...
  • Page 24: Fan Wiring Diagram

    FAn WIrIng dIAgrAM FOr usE WITH THE OpTIOnAL 396-917 FAn FOr L390E/HZI390E) Grounding Ground wire Lug Detail Ground from fan Lockwasher Star washer Neutral Green Live Star washer Ground Ground wire 120V AC from power cord Black Black Rotary Speed...
  • Page 25: Optional Wall Thermostat Installation

    3) Connect one thermostat lead to female connector, using male spade con- nector - see pic below. When complete turn remote receiver to the ON position. Unit will now operate using the wall thermostat. L390E / HZI390E Direct Vent Gas Insert...
  • Page 26: Glass Crystal / Ceramic Spa Stone Installation

    NOTE: * Glass Crystals are available in 1lb and 5lb bags. All units come standard with Cobalt Blue glass crystals except: * HZO42 comes with Copper glass crystals. * HZI390E, HZI390EB, HZI540EB, PTO30, PTO60 & Plateau Series do NOT include glass crystals with units. Must purchase separately. • 1 Ceramic Spa stone package contains 70 stones.
  • Page 27 HZI390E ADDENDUM installation CAUTION DO NOT place spa stones or volcanic stones over pilot and burner ports. No spa stones in this areas. No volcanic stones in this area. L390E / HZI390E Direct Vent Gas Insert 09/28/11...
  • Page 28: Optional Pebbles / Glass Crystal Installation

    Natural River Pebbles shown surrounding the a Horizon Burner Glass Crystals shown surrounding the Burner River Pebbles shown surrounding a Sunrise Burner L390E / HZI390E Direct Vent Gas Insert...
  • Page 29: L390E /L390Eb Log Set Installation

    Log 2 should sit fl at and not rock. Log 1 pins on burner tray 2) Identify corresponding locators on bottom of Log 1 - see below. Log 1 locators 03/30/11 919-008 L390E / HZI390E Direct Vent Gas Insert...
  • Page 30 7) When installed - ensure the air gap at the rear of the log is maintained - as indicated by arrow below. Log 5 - correct position R Log 5 - correct position L Log 5 - correct position installed L390E / HZI390E Direct Vent Gas Insert 919-008 03/30/11...
  • Page 31 11) Match up pin on Log 5 with locator on Log 6 as shown below. 12) Place Y of Log 6 as shown below. Final Install "Y" in Log 6 L390E / HZI390E Direct Vent Gas Insert 919-008 03/30/11...
  • Page 32: Standing Pilot And Heat Exchange Return

    And HEAT ExcHAngE rETurn The L390E / HZI390E use a heat exchanger and efficient combustion technology to provide extreme heating efficiencies. The more efficient an ap- rEMOVIng THE HEAT ExcHAngEr rETurn pliance becomes, the lower the flue gas temperatures becomes.
  • Page 33: Brick Panel Installation

    8) Snug the Firebox Liner Retainers up against the Firebox Liner Left & Right. Using a screw driver, secure the screws that hold down each retainer. 9) Reinstall burner - see ceramic burner installation section in manual. L390E / HZI390E Direct Vent Gas Insert 03/14/12 919-024a...
  • Page 34: Enamel Panel Installation

    5) Push the fi rebox liner retainers against the panels, pushing the panels tight against the fi rebox sides. Secure the screws that hold down the fi rebox liner retainers (x4). 6) Reinstall burner. L390E / HZI390E Direct Vent Gas Insert 11/07/11 919-025...
  • Page 35: Glass Door Removal / Installation

    6) Pull the bottom of the door towards you until the door is angled away from the firebox by about 30°. Lift the door up and over the upper door hooks. 7) To install the glass door - reverse steps. L390E / HZI390E Direct Vent Gas Insert...
  • Page 36: Sided Low Profile Faceplate Installation

    L390E / HZI390E / L540E / HZI540E installation 3 sIdEd LOW prOFILE FAcEpLATE InsTALLATIOn 3 sIdEd LOW prOFILE FAcEpLATE InsTALLATIOn Note: A mantel defl ector may be installed to reduce the minimum mantel height. 4) Install front faceplate and secure to the unit with 4 screws in locations Refer to minimum clearances in the installation manual.
  • Page 37: Sided Low Profile Faceplate Installation

    Note: Faceplate may be installed after the unit is in it's fi nal position. Trim 3) Install Low Profi le faceplate backing plate and secure to the unit with 4 screws in locations shown below. Final Install L390E / HZI390E Direct Vent Gas Insert 09/26/11 919-023a...
  • Page 38: Optional Hearth Trim Installation

    Hearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace. ** If no screw holes are present. 1) For units L390E/HZI390E/L540E/HZI540E–remove 4 screws in locations shown below to remove outer faceplate.
  • Page 39: Optional Screen Installation

    Locations shown in the diagrams below. Tabs 2) Secure the screen by placing provided magnets between the back of the screen and the unit in locations shown below. 3) To remove - reverse steps. L390E / HZI390E Direct Vent Gas Insert 919-022a 09/22/11...
  • Page 40: Optional Full Screen Door Installation

    . The tabs should be fl ush with the underside of the top lip of the back plate. Top of backing plate 3) Install the optional full screen to the unit by securing with 4 screws in locations shown below. Final Install L390E / HZI390E Direct Vent Gas Insert 09/26/11 919-027a...
  • Page 41: Operating Instructions

    3) Turn the gas control knob to the "OFF" position turned off and the unit cooled to below a useful to turn off the pilot. heat output range the fan will shut off automatically. L390E / HZI390E Direct Vent Gas Insert...
  • Page 42: Normal Operating Sounds Of Gas Appliances

    Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628b L390E / HZI390E Direct Vent Gas Insert...
  • Page 43: Maintenance

    1 flow- ing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner). Window Glass Door Components L390E / HZI390E Direct Vent Gas Insert...
  • Page 44: Pilot Adjustment

    NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty. gLAss gAsKET If the glass gasket requires replacement use glass gasket for the Flush Front (Part # 936-112). L390E / HZI390E Direct Vent Gas Insert...
  • Page 45: Glass Crystal Burner Removal / Installation

    MAInTEnAncE gLAss crysTAL BurnEr rEMOVAL / InsTALLATIOn (HZI390E / HZI390EB) gLAss BurnEr InsTALL Disconnect unit from gas supply and allow unit to cool before removing burner. 1) Lift the burner assembly with both hands. Point the mixing tube towards gLAss BurnEr rEMOVAL the rear of the firebox.
  • Page 46: Glass Burner Install

    Ceramic Burner and the firebox Bottom Flange. The Burner should be situated about ¼” (6mm) inside the front edge of the firebox. 4) To install - reverse Steps 3-2, see Step 1 for correct installation tips. L390E / HZI390E Direct Vent Gas Insert...
  • Page 47: Fan Maintenance - With Gtmf Remote Control

    This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the Diagram 2 grounding prong from this plug. L390E / HZI390E Direct Vent Gas Insert...
  • Page 48: Valve Replacement

    3) Disconnect the Pressure Regulator cable. 7) Remove both Screws that secure the Gas Valve Mounting brackets, both sides. Pressure regulator cable 4) Disconnect the Gas Orifice supply line from the outlet of the Gas Valve. L390E / HZI390E Direct Vent Gas Insert...
  • Page 49 15) Reconnect the gas and electrical supply to the unit. Once the unit has be re-fired, use a soapy water mixture to check all fittings and gas sup- ply lines for gas leaks. L390E / HZI390E Direct Vent Gas Insert...
  • Page 50: Parts List

    SIT Proflame receiver 904-790 Magnets 911-074 Pilot Assy Ground Wire 919-090 Manual 396-043 Firebox Liner Retainers Not Shown 396-114 Burner End - L 911-071/P Fan Motor Only 910-142 Fan Thermodisc 911-030 Fan Control Module L390E / HZI390E Direct Vent Gas Insert...
  • Page 51 L390E / HZI390E Direct Vent Gas Insert...
  • Page 52: Low Profile Faceplate

    396-103 3 sided low profile backing plate 396-102 3 sided low profile front face 396-130 4 sided low profile backing plate 396-129 4 sided low profile front face 396-127 Low profile bottom cover L390E / HZI390E Direct Vent Gas Insert...
  • Page 53 L390E / HZI390E Direct Vent Gas Insert...
  • Page 54 L390E / HZI390E Direct Vent Gas Insert...
  • Page 55: Warranty

    WarrantY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 56 ® register your regency warranty online www.regency-fire.com reasons to register your product online today! • View and modify a list of all your registered products. • request automatic email notification of new product updates. • stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

L390e

Table of Contents