Regency Fireplace Products H2104 Owners And Installation Manual

Wood fireplace insert & hearth heater
Hide thumbs Also See for H2104:

Advertisement

WOOD
Fireplace Insert &
Hearth Heater
Owners & Installation Manual
www.regency-fi re.com
MODELS:
H2104
I3104L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-035
05/02/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H2104 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products H2104

  • Page 1 Fireplace Insert & Hearth Heater Owners & Installation Manual www.regency-fi re.com MODELS: H2104 I3104L Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
  • Page 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
  • Page 3: Table Of Contents

    Optional Flue Connector Kit ..........7 Door Gasket ..............15 Masonry and Factory Built Fireplace Clearances ..7 Door Latch Adjustment ..........15 Leg Option on H2104 Hearth Heater ......8 Glass Cleaning ............15 Flue Connector Bracket ..........8 Glass Replacement .............15 Installation Into a Factory Built Fireplace.......8 Glass Removal ............15...
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Large Flush Insert. We have printed improved. Check the label on the unit and if a copy of the contents here for your review. there is a difference, the label on the unit is the correct one.
  • Page 5: Safety Label For H2104M

    SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Hearth Heater. We have printed a improved. Check the label on the unit and if copy of the contents here for your review. there is a difference, the label on the unit is the correct one.
  • Page 6: Installation

    INSTALLATION Regency Inserts are constructed with the high- CHIMNEY 9) Inserts that project in front of the fi replace est quality materials and assembled under strict must be supplied with appropriate supporting SPECIFICATIONS quality control procedures that insure years of means.
  • Page 7: Optional Flue Connector Kit

    INSTALLATION Position the grill on the inside bodyface side OPTIONAL FLUE and fasten using the bolts, washers and nuts CONNECTOR KIT provided (2 per side) as shown in the diagrams. The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl...
  • Page 8: Leg Option On H2104 Hearth Heater

    Detailed installation instructions are is used. included with the kit. BRACKET LEG OPTION ON H2104 2) Direct fl ue connection, where a smaller blocking plate and a connector pipe to the HEARTH HEATER Package contains: 3 brackets and 6 screws.
  • Page 9: Faceplate And Trim

    INSTALLATION FACEPLATE AND TRIM 4) If the fl oor of your fi replace is below the level of the fi replace opening, adjust the A) H2104M and I3104L Insert insert's levelling bolts to accommodate the Prior to sliding your insert into its fi nal position difference.
  • Page 10: Stainless Smoke Defl Ector Install

    INSTALLATION STAINLESS STEEL SMOKE DEFLECTOR ADJUSTMENT / REPLACEMENT The stainless smoke defl ector is located in the upper front area of the fi rebox. The defl ector is held in place with 2 bolts Prior to the fi rst fi re, ensure defl ector is seated properly and secured with 2 hand tightened bolts. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening.
  • Page 11: Fan / Blower

    INSTALLATION and the fi replace face. The faceplate top may now be installed (with insulation strip behind) by aligning its brackets with the top fl ange on the side shields and the angle iron bar on the insert top. The faceplate trim may be installed to the edge of the faceplate at this time. Installer: Please record unit serial number here before installing blower.
  • Page 12: Firebrick Assembly

    INSTALLATION BRICK FLUE BAFFLE & 2) Slide the supports into the clips. The tension SECONDARY AIR TUBE holding the clips in place may be adjusted by increasing or decreasing the offset spacing INSTALLATION of the clips. 3) Ensure that the power cord is not in contact The fl...
  • Page 13: Floor Protection

    INSTALLATION FLOOR PROTECTION not obstruct the smoke from getting up the fl ue SCREEN DOOR opening. This insulating batt may be wrapped in paper for handling purposes and does not Please check to ensure that your fl oor protection Hook screen to the inside on the right side require removal.
  • Page 14: Operating Instructions

    OPERATING INSTRUCTIONS becomes seasoned. Windows and/or doors of the Inserts and it controls the intensity of the The fan is to be operated only with the draft fi re by increasing or decreasing the amount of should be left open to provide adequate control rod pulled out at least 1/2"...
  • Page 15: Creosote

    MAINTENANCE 2) Keep the door closed during operation and Have the chimney cleaned before the burning maintain all seals in good condition. season and as necessary during the season, as The gold electroplated fi nish on the doors creosote deposits may build up rapidly. Moving requires little maintenance, and need only be 3) Do not burn large quantities of paper in your parts of your insert require no lubrication.
  • Page 16: Parts List

    PARTS LIST I3104 MAIN ASSEMBLY Part # Description 850-152 Door Assembly - Large Gold (I3104) 850-151 Door Assembly - Large Black (I3104) 850-153 Door Assembly - Large Nickel Accent (I3104) 850-154 Door Assembly - Large Gold Accent (I3104) 846-304 Glass - Replacement - (I3104) 936-243 7/8"...
  • Page 17: I3104 Faceplates

    PARTS LIST I3104 FACEPLATES Part # Description Faceplate: I3104L 163-910 Faceplate & Trim Set - Regular 163-570 Black Trim Regular (Set of 3) 385) * Trim Right Regular 386) * Trim Top Regular 387) * Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate Top Regular...
  • Page 18: H2104 Main Assembly

    PARTS LIST H2104 MAIN ASSEMBLY Part # Description Part # Description 37) 836-212 Baffl e Insulation 850-152 Door Assembly - Large Gold 38) * Insulation Weights 850-151 Door Assembly - Large Black 39) 120-950 Steel Baffl e 850-153 Door Assembly - Large Nickel Accent...
  • Page 19: I3104 & H2104 Firebrick

    PARTS LIST I3104 & H2104 FIREBRICK Part # Description 120-960 H2104 Brick Set Complete 163-960 I3104 Brick Set Complete 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) * Brick Partial: 1-1/4" x 4" x 9" 72) * Brick Partial: 1-1/4"...
  • Page 20 NOTES Regency Wood Insert & Hearth Heater...
  • Page 21 NOTES Regency Wood Insert & Hearth Heater...
  • Page 22 NOTES Regency Wood Insert & Hearth Heater...
  • Page 23: Warranty

    WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 24 ® Register your Regency warranty online www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

I3104l

Table of Contents