OPERATING
INSTRUCTIONS
1) Read and understand these instructions before
operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Ensure that the stainless panels are installed.
5) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have been
incorrectly positioned.
6) The unit should never be turned off, and on
again without a minimum of a 60 second wait.

LIGHTING PROCEDURE

1) Turn on ON/OFF switch.
2) After approximately 4 seconds the spark igni-
tion system will spark for 60 seconds to light
the main burner.
3) The unit will turn on.
Note: The first try for ignition will last approximately
60 seconds. If there is no flame ignition (rectifi-
cation) the board will stop sparking for approxi-
mately 35 seconds. After wait time , the board
will start second try for ignition by sparking for
approximately 60 seconds . If there is still no
positive ignition the board will go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch.
b)
After approximately 2 seconds turn on ON/
OFF switch.
c) Unit will repeat step 2.
SHUTDOWN
PROCEDURE
1) Turn ON/OFF switch.
2) If service is to be performed - you must discon-
nect both sources of power to the unit, the main
power and battery.

FIRST FIRE

The first fire in your fireplace is part of the paint
curing process. To ensure that the paint is properly
cured, it is recommended that you burn your fireplace
for at least four (4) hours the first time you use it
.
When first operated, the unit will release an odour
caused by the curing of the paint, the burning off of
any oils remaining from manufacturing.
The glass panel may require cleaning after the unit
has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.

operating instructions

AERATION
ADJUSTMENT
Open the air shutter for a blue flame or close for a
yellower flame. The burner aeration is factory set
but may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
1/8"
1/4"
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning resulting from
improperly setting the aeration controls is NOT
covered under warranty.
Note: Aeration Adjustment should only be per-
formed by an authorized FPI Installer at the
time of installation or service.