Regency Fireplace Products HZO42-NG Owners & Installation Manual

Hzo42 series outdoor gas fireplace
Hide thumbs Also See for HZO42-NG:

Advertisement

Regency HZO42 Outdoor
www.regency-fire.com
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Read the installation, operating and maintenance instructions thoroughly before installing
or servicing this equipment.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-976c
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
MODELS: HZO42-NG
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4565 / NZS 4558
and have been certified by the IAMPO
Oceana for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
WARNING: FOR OUTDOOR USE ONLY
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Owners &
HZO42-ULPG
04.09.15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HZO42-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency Fireplace Products HZO42-NG

  • Page 1 Owners & Regency HZO42 Outdoor Installation Manual Gas Fireplace MODELS: HZO42-NG HZO42-ULPG LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4565 / NZS 4558 and have been certified by the IAMPO Oceana for installation and operation as described in these Installation and Operating Instructions.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The HZO42 Outdoor fireplace ® has been designed to provide you with all the warmth and charm of a fire at the flick of a switch. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    table of contents DATA BADGE Glass crystal / garden stone installation .....18 Pebble installation ............19 Volcanic stone installation ...........20 Optional Log Set Installation........21 Data Badge..............5 Heat deflector installation ..........23 Faceplate installation ...........24 DIMENSIONS Glass wind shield installation........25 Weather cover installation / removal ......25 Unit Dimensions ............5 OPERATING INSTRUCTIONS INSTALLATION...
  • Page 4: Data Badge

    safety decal This is a copy of the data badge that accompanies each HZO42 Outdoor Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being ® improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 5: Dimensions

    dimensions UNIT DIMENSIONS 37 - 13/16” (960mm) 41 - 11/16” (1059mm) 43 - 11/16” (1110mm) 16 -1/2” (491mm) 43-1/4” (1099mm) 15 - 1/4” (387mm) 13 - 7/16” (341mm) 5/8” (16mm) Regency HZO42 (Aus) Gas Fireplace...
  • Page 6: Installation

    installation IMPORTANT MESSAGE 5) To prevent injury, do not allow anyone who is DO NOT USE THIS APPLIANCE IF unfamiliar with the operation to use the fireplace. SAVE THESE ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED 6) Wear gloves and safety glasses for protection INSTRUCTIONS while doing required maintenance.
  • Page 7: Installation Checklist

    installation LOCATING YOUR INSTALLATION GAS FIREPLACE CHECKLIST 1) This appliance must only be used in a well ventilated area. Installation in accordance with AS/NZS5601. 2) When selecting a location for your fireplace, ensure that the clearances are met. 1) Locate appliance: 3) This appliance must be installed in an open-air situation with natural ventilation, without stagnant a) Refer to "Locating Your Gas fireplace"...
  • Page 8: Components In Outdoor Appliances

    installation IMPORTANT INFORMATION FOR OUTDOOR FIREPLACE INSTALLATIONS IMPORTANT THINGS TO REMEMBER • Never insulate around the body of the unit • Excessive heat retention in the firebox will lead to component failure • Correct Working Gas pressure is critical on “E” units and fireplace malfunction •...
  • Page 9: Minimum Clearances To Combustibles

    installation MINIMUM CLEARANCES TO COMBUSTIBLES The clearances listed below are Minimum distances unless otherwise stated: A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
  • Page 10: Framing Dimensions

    installation FRAMING DIMENSIONS Framing Description HZO42 Dimensions Header Height 32-11/16” (30mm) Side Stud Width 42 - 3/16" (1072mm) Minimum framing depth 20" (508mm) Minimum Height to Combustibles 52 - 1/2" (1334mm) Minimum framing width 60" (1524mm) Corner Wall Depth 40 - 7/16" (1027mm) Corner Facing Wall Width 54 - 3/16"...
  • Page 11: Mantel Clearances

    installation MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 26”(660mm) Note: Ensure the paint that is used on the mantel and the 12"...
  • Page 12: Finishing

    installation FINISHING IMPORTANT FINISHING DETAIL NOTE: Before placing unit into final position - it is important to know the total thickness / height of finished hearth. The base of the fireplace should be level or higher than the finished hearth height. If material such as brick, stone, etc extends past the faceplate depth (1-1/2"...
  • Page 13: Gas Line Installation

    PILOT ADJUSTMENT 880 S.I.T. VALVE HZO42-NG SYSTEM DATA DESCRIPTION Max. Supply Pressure 14" WC (3.49 kpa) Periodically check the pilot flames. Correct flame Min. Supply Pressure 5" WC (1.25 kpa) pattern has two strong blue flames: 1 flowing Manifold Pressure 3.5"...
  • Page 14: Unit Assembly Prior To Installation

    installation UNIT ASSEMBLY PRIOR TO INSTALLATION NAILING STRIPS The 6 Standoffs must be correctly positioned and attached before unit is slid into position. The nailing strips come attached to the unit. There is 1 plate on each side and 1 on the top that can be folded out as required. Secure the top and side nailing strips to the framing.
  • Page 15: Wall Switch Installation(Included With Unit)

    installation WALL SWITCH INSTALLATION (INCLUDED WITH UNIT) The unit comes with 10' of wire located on the left side of the unit. Install supplied electrical box in desired location. Route low voltage wire through electrical box. Connect 2 wires to switch (use supplied dielectric grease on connections) Install weather resistance cover plate to switch using 2 inner holes with screws provided.
  • Page 16: Wiring Diagram

    installation WIRING DIAGRAM This heater does not require a 240V A.C. supply for operation. (Do not cut the ground terminal off under any circumstances.) NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Proflame SureFire™...
  • Page 17: Inner Panel Installation

    installation HZO42 PANEL INSTALLATION INNER PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration.
  • Page 18: Glass Crystal / Garden Stone Installation

    installation GLASS CRYSTALS OR OPTIONAL SPA / CERAMIC / VOLCANIC STONES INSTALLATION ON BURNER *See unit manual for detailed installation instructions. GLASS CRYSTAL / GARDEN STONE INSTALLATION Spread the Glass Crystals or Stones evenly over the burner. Ensure the crystals/stones do not overlap excessively as this will affect the fl ame pattern. IMPORTANT NOTE: Only the supplied approved Glass Crystals and Stones are to be used with these fi replaces.
  • Page 19: Pebble Installation

    OPTIONAL PEBBLES / GLASS CRYSTAL INSTALLATION FOR FIREBOX BASE (AROUND BURNER) installation PEBBLE INSTALLATION Firebox (Around Burner) Packages Unit Glass Crystals Pebbles HZ54E / HZ54EPV 6 lbs 2 packages (6 x bags pebbles) HZ42 / HZ42E/HZ40E 5 lbs 2 packages (6 x bags pebbles) HZ42ST / HZ42STE / HZ42STEPV 5 lbs 2 package (6 x bags pebbles) HZ30E...
  • Page 20: Volcanic Stone Installation

    installation VOLCANIC STONE INSTALLATION OPTIONAL VOLCANIC/GARDEN STONES INSTALLATION ON BURNER Evenly spread the glass crystals and volcanic stones over the burner. Ensure the stones do not overlap too much as this will effect the fl ame pattern. IMPORTANT NOTE: Only the supplied approved Volcanic Stones are to be used with these fi replaces. Use of any other type of stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
  • Page 21: Optional Log Set Installation

    OUTDOOR 42 installation LOG SET INSTALLATION OPTIONAL LOG SET INSTALLATION Installation of Refl ective Panels must be completed before installing the log set. Installation of Reflective Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced.
  • Page 22 installation OUTDOOR 42 4) Install log D on the burner as shown below. Orient log D across log E in the same way and in a similar position as depicted in Diagram 5- log D will rest up against the back panel. Diagram 5 5) Install log F on the right side of the burner as shown below.
  • Page 23: Heat Deflector Installation

    installation HEAT DEFLECTOR INSTALLATION 1) Install the heat deflector to the top inside of the firebox with 4 screws as shown below. Heat Deflector Heat Deflector Installed Regency HZO42 (Aus) Gas Fireplace...
  • Page 24: Faceplate Installation

    installation FACEPLATE INSTALLATION Remove the protective coating from the faceplate before installation - see For installations where thicker finishing material is used - the optional handling instructions in panel install section. trim piece may be installed to fill the gap. Install the trim in front of the bottom access panel as shown below.
  • Page 25: Glass Wind Shield Installation

    installation GLASS WIND SHIELD INSTALLATION 1) To install the glass wind shield - slot it into the space between the burner tray cover and the bottom access panel. Burner Tray Cover Glass Wind Shield Bottom Access panel WEATHER COVER INSTALLATION / REMOVAL 1) The unit should be covered when not in use for extended periods of time.
  • Page 26 OUTDOOR 42 installation ASSEMBLY INSTRUCTIONS FOR A STEEL STUD FRAMING KIT FOR HZO42 ASSEMBLY INSTRUCTIONS FOR A STEEL STUD FRAMING KIT FOR OUTDOOR 42 Follow these instructions to construct a steel stud frame for the Outdoor fi replace; Overall dimensions = 70-15/16" (1801mm) W x 20" (508mm) D x 47-5/16" (1201mm) H. **Non-combustible fi...
  • Page 27 OUTDOOR 42 installation 1) Place top/bottom (A) on the ground - fl at side down. Bend 3) Line up the screw holes of (A) with (B). Secure the tabs up to a 90° angle. each (B) with 2 wafer screws (one on each side) as shown below.
  • Page 28 OUTDOOR 42 installation 6) Manoeuvre remaining (B) pieces and position in each corner 9) Position remaining 2 - (C) pieces offset from center rib as of the frame - fl at side facing out - see 2 diagrams below. shown below. 10) Position (D) on top of (C) pieces - line up screw holes and secure (D) to (C) with 12 wafer screws.
  • Page 29 OUTDOOR 42 installation 12) LIne up screw holes on (E) (header) and (B) (inner vertical 14) Line screw holes on 1 (F) (corner brace) with (B) + (A) and support). Secure with 2 wafer screws on each side (4 total) secure with 4 wafer screws.
  • Page 30 installation REMOTE PROPANE / ULPG GAS ENCLOSURES INSTALLATION GUIDELINES If the unit is permanently connected to a gas piping system • Bottom opening must provide a minimum of 12mm from a remote supply tank, installation must be in accor- square(3.23 cm²) for each pound of propane/ULPG dance with local codes or, in absence of local codes, with the contained in the tank (see example below).
  • Page 31: Operating Instructions

    operating instructions OPERATING FIRST FIRE AERATION INSTRUCTIONS ADJUSTMENT The first fire in your fireplace is part of the paint curing process. To ensure that the paint is properly 1) Read and understand these instructions before Open the air shutter for a blue flame or close for a cured, it is recommended that you burn your fireplace operating this appliance.
  • Page 32: Copy Of Lighting Plate Instructions

    operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS The lighting plate is located on the underside of the front access panel in the unit. A) This appliance is equipped with an ignition device which automatically lights the pilot. FOR YOUR SAFETY READ BEFORE LIGHTING Do not try to light the pilot by hand.
  • Page 33: Maintenance

    maintenance MAINTENANCE INSTRUCTIONS YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUS- CEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSI- 1) Always turn off the gas valve and unplug the batteries before cleaning. CAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK For relighting, refer to lighting instructions.
  • Page 34: Valve Assembly Replacement

    maintenance VALVE ASSEMBLY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 9) Remove the front access panel by lifting up and out. 2) Turn off the gas supply to the unit. 3) Remove trim. 4) Remove the faceplate by lifting it up and off the unit.
  • Page 35: Battery Replacement

    maintenance BATTERY REPLACEMENT 12) Slide the burner to the right and lift up and out of the firebox. 1) Remove the 2 screws securing the battery compartment. 13) Remove the 5 screws securing the Digital Fireplace Burner Control to the 2) Lift the battery compartment upwards.
  • Page 36 maintenance DIGITAL FIREPLACE BURNER CONTROL REMOVAL 1) To access to the Digital firebox burner control box - follow steps 1-11 from 5) Disconnect the yellow ground wire with green diagonal stripe for pilot the Valve assembly replacement instructions on pages 35,36. (CN2).
  • Page 37: Main Assembly

    parts list MAIN ASSEMBLY Part # Description 326-028 Pilot Hood 1) 326-554 Faceplate Assembly 326-036 Top nailing strip 326-036 Side nailing strip 2) 326-072 Heat Deflector 3) 940-368/P Wind Shield 4) 326-525 Burner Assembly NG/LPG/ULPG 948-223 Logo Plate 326-073 Weather Cover 5) 904-777 Orifice # 29 (NG) 911-976...
  • Page 38: Burner Assembly

    parts list BURNER ASSEMBLY Part # Description Part # Description 326-525 Burner Assembly NG 904-660 Orifice #29 NG 326-525 Burner Assembly ULPG 904-431 Orifice #47 LPG/ULPG 10) 911-024 Valve NG SIT 880 326-930 Log Set 911-025 Valve LPG/ULPG SIT 880 11) 326-008 Burner Tray Cover 12) 911-006...
  • Page 39: Accessories

    parts list ACCESSORIES Part # Description Reflective Stainless Steel Inner Panels 326-021 Rear panel staniless 326-022 Left Panel Stainless 326-023 Right Panel Stainless 14) 940-368/P Glass windshield 15) 326-554 Faceplate Brushed Stainless 946-676 Copper Glass Crystals 946-695 Garden Stones Regency HZO42 (Aus) Gas Fireplace...
  • Page 40 notes 40 | Regency HZO42 (Aus) Gas Fireplace...
  • Page 41 notes Regency HZO42 (Aus) Gas Fireplace...
  • Page 42: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 43: Limited Warranty

    DISTRIBUTORS: Western Australia Eastern Australia Air Group Australia Fireplace Products Australia PTY. Ltd. 28-30 Division St. 1-3 Conquest Way Welshpool, WA 6106 Hallam, VIC 3803 08 9350 2200 03 9799 7277 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY...
  • Page 44 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Hzo42-ulpg

Table of Contents