5. Plug in the supplied AC adaptor and run the wire through the bottom
of the outer box, be sure to use a grommet to protect the wire.
6. Run the AC adaptor wire from the recently installed electrical box, to
the back of the unit end.
7. Attach the AC adaptor to the DC supply wire. Secure wire using a
strain relief ( see enclosed picture) Reinstall the valve cover plate
(reverse Step 6).
Back of
unit housing
Strain
Relief
PTO30/PTO50/HZO60
8. Remove the valve cover plate on side of unit to expose the DC supply
wire by removing 6 screws (PTO30/PTO50/HZO60 only)
NOTE: The valve cover plate should be removed prior to being installed
into the framing kit or framing in general for ease of access to these 6
screws. This would also apply when reinstalling the valve cover plate.
9. HZO42/HZO60 only--Remove the front access panel by lifting up and
out.
919-774
HZO42
Valve cover plate
(PTO30/PTO50/HZO60 only)
2
10. HZO42/HZO60--Remove the burner tray by lifting up and out.
HZO42 only- remove 6 screws in locations shown below to access DC
supply.
6th screw located at back
11. Locate the 'DC supply' wire on the wiring harness,the wire will be
clearly marked. See 'AC Adaptor Install' in the manual.
12. Secure protective cover with lid to the receptacle box with 4 screws.
13. Install cover onto outer box.
Outer cover
14. Turn on gas and electrical supply and test unit.
15. PTO100 Only:
If a second AC adaptor is required to power a second burner, repeat
steps 5-9.
Regency Horizon® HZO42 Gas Fireplace