No Key/Card at
When no Key/Card is present at a Reader, the LEDs will indicate the system status, as follows:
Reader
Red LED ON----at least one of the Reader partitions is Armed
Red LED OFF----all the Reader partitions are Disarmed
Amber LED ON----the system is armed in Type A mode
Green LED ON----the system is armed in Type B mode
The LEDs will indicate the status of the Reader partitions only. The Reader LEDs can be programmed to show Panel
status at all times, or only in response to a valid Key (LEDs OFF when the Reader is empty).
If the configuration of the armed partitions does not match either Type A or B arming mode, the Amber and Green
LED will not switch ON (for example, a Reader partition has been armed from a keypad).
Key/Card at
When a Key/Card is present at a Reader, the LEDs will indicate the system status, as follows:
Reader
The Control panel will perform a 'Zones Check' on the Unbypassed and Instant zones----of the partitions to be armed. If
violated zones are found (door or window open), the LED (assigned to the selected Arming mode) will flash to signal
that arming the partitions will generate an alarm.
+
If violated zones, found during a 'Zones Check', are programmed as Auto-bypassable, they will be bypassed,
and an alarm will not be generated. Zones bypassed in this way will be unbypassed when their partitions are next
disarmed.
False Keys/Cards at Readers will be signalled by fast blinking on all three LEDs, and will generate False Key/Card
events that in turn will activate the programmed actions.
n Global arming
This operation will arm all the partitions of the Key/Card and Reader in use.
All 3 LEDs must be OFF.
n Global disarming
This operation will disarm all the partitions of the Key/Card and Reader in use.
The Red LED must be ON.
n Type A arming (Amber)
This operation will arm specific partitions and disarm others, as per the programmed configuration.
The Amber LED must be ON.
n Type B arming (Green)
This operation will arm specific partitions and disarm others, as per the programmed configuration.
The Green LED must be ON.
n Stop Alarm
This operation will interrupt all the alarms generated by the partitions of the Key/Card and Reader in use.
To Stop Alarms: use a valid key at a Reader. If the Enable Panel-Alarm Stop with valid Electronic Key option
is enabled, the Control panel alarms will also be interrupted.
+
If the Key/Card has been programmed to stop calls----the ongoing call will be interrupted and the call queue will be
cleared.