Restoring Factory Defaults
SecurePlatform
Use the SecurePlatform WebUI to restore the default factory settings.
To restore a SecurePlatform appliance with the WebUI:
1. Open Internet Explorer and navigate to the management IP address,
https://<appliance_ip_address>:4434
2. Log in to the WebUI of the appliance using the administrator username and password.
3. In the WebUI, click Appliance > Image Management.
The Image Management window opens.
4. Select the image version that you are restoring.
5. Click Revert.
Restoring Using the Console Boot Menu
To restore the appliance using the console boot menu:
1. Connect the supplied serial cable's RJ45 connector to the console port on the front of the
appliance.
2. From the computer, open a terminal emulation program such as Microsoft HyperTerminal
or PuTTY.
3. Configure the terminal emulation program:
•
In the HyperTerminal Connect To window, select a port from the Connect using list.
•
In PuTTY select the Serial connection type.
4. Define the serial port settings: 9600 BPS, 8 bits, no parity, 1 stop bit.
5. From the Flow control list, select None.
6. Connect to the appliance.
7. Turn on the appliance.
36
|
Check Point 4000 Appliances Getting Started Guide
Need help?