d&b audiotechnik 10D Manual page 91

Hide thumbs Also See for 10D:
Table of Contents

Advertisement

Id
Display text
122
CAN warning
124
OCA remote error
150
Speaker imp. fault
153
Amp. low
temperature
160
Input fallback
161
Input monitoring fault Input monitoring fault
162
Input monitoring fault Input monitoring fault
163
Input monitoring fault Input monitoring fault
164
Input monitoring fault Input monitoring fault
165
Input monitoring fault Input monitoring fault
166
Input monitoring fault Input monitoring fault
167
Input monitoring fault Input monitoring fault
168
Input monitoring fault Input monitoring fault
169
Ethernet overload
d&b 10D/30D Manual 1.10 en
Eventlog text
Description
CAN warning %d
CAN warning
(remote flags %02X,
dbCan flags %02X)
OCA remote error
OCA remote error
%u
(empty)
Load Monitoring
impedance error
Channel '%c': Amp.
Amp temperature
temperature too low
warning
(%d°C)
Input fallback (A1=
Input fallback was
%d, A2=%d, D1=%d,
activated
D2=%d)
Input monitoring fault (External: Cabling)
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
A%d (%4.1ddBu,
threshold %4.1ddBu)
Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Input monitoring fault
D%d (lock %d,
%4.1ddBFS,
threshold
%4.1ddBFS)
Ethernet overload,
Ethernet overload
throttling active
Location
Possible reasons
(External: CAN
CAN cabling or
cabling)
multiple RemIds.
Software error.
(External: speaker,
Speaker defect,
cabling)
cable.
Amp
Ext. conditions, sensor
fault.
(External: Cabling)
Cabling or signal
source defect.
Too much network
traffic.
91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30d

Table of Contents