d&b audiotechnik 10D Manual page 45

Hide thumbs Also See for 10D:
Table of Contents

Advertisement

d&b 10D/30D Manual 1.10 en
Selecting «Override» from the «Input settings» menu opens the
corresponding subscreen.
Off
Disables the function.
The On/Off status is also displayed on the
«Input settings» screen.
Manual
The desired signal path («Source») can be selected
manually either locally or via the Web Remote
interface or via the d&b Remote network using R1.
Auto
With this mode selected, the analog input A3 is
permanently monitored.
As soon as the incoming signal level exceeds the
defined threshold, input A3 will be opened
depending on the set Attack time. All other channels
will be muted (Gate + Ducking).
As soon as the signal level drops below the
threshold, input A3 will be muted while all other
channels will be unmuted depending on the set
Hold and Release times (crossfade).
Threshold
Threshold level, adjustable from –42 dBu to
+25 dBu in 1 dBu increments.
At the bottom left, the actual level of the incoming
signal is displayed in light grey. In addition, an LED
indicator is provided at the top right. As long as the
incoming signal level is below the set threshold, the
LED illuminates yellow and changes to green as
soon as the level exceeds the threshold.
Attack
Attack time, adjustable from 0.01 sec. to 1 sec. in
0.01 sec. increments.
Hold
Hold time, adjustable from 0 sec. to 10 sec. in
0.1 sec. increments.
Release
Release time, adjustable from 0 sec. to 10 sec. in
0.1 sec. increments.
45