d&b audiotechnik 10D Manual page 90

Hide thumbs Also See for 10D:
Table of Contents

Advertisement

Id
Display text
46
Amp. firmware is too
old
50
Invalid device para
51
Invalid DSP prog %u
52
DSP boot error
58
DSP comm. error
59
Invalid setup data
61
Invalid AP slot %d
78
Amp. supply fault
79
Amp. firmware
mismatch
87
Amp temp. mute
89
Amp. protection
95
Amp. overtemp %dÂ
°C
96
Amp. temp sensor
fault
99
Amp. temp warn
%d°C
120
CAN open error
121
CAN error
90
Eventlog text
Description
Amp. firmware
Amp firmware version
version %4.2d is too
is older than required
old, required is
%4.2d
Channel '%c': invalid
Invalid device
device parameters
parameters
(device ident %d)
Channel '%c' : invalid
DSP program invalid
DSP program %d
Channel '%c': DSP
DSP boot error
boot error (DSP
program %d)
Channel '%c': DSP
DSP communication
communication error
fault
Channel '%c': invalid
DSP invalid setup
speaker setup
data
(speaker id %d, no.
%d, err %d)
Channel '%c': invalid
Invalid
AP slot %d (file
ArrayProcessing data
version %d)
Amp. supply fault
Amp rail voltages
(status %04X, err
%04X, %4.1dV,
%4.1dV)
Amp. firmware V%d.
Amp has wrong
%02d.%02d not
firmware
suitable for hardware
ident %d
Channel '%c': Amp.
Amp mute due to
temperature auto
high temperature
shutdown (%d°C)
Channel '%c': Amp.
Amp channel
protection (power
protection
%uW)
Channel '%c': Amp.
Amp over
overtemperature %dÂ
temperature
°C (power %uW)
Amp. temperature
Amp temperature
sensor fault (A %dÂ
sensor fault
°C, B %d°C, C
%d°C, D %d°C)
Channel '%c': Amp.
Amp temperature
temperature warning
warning
%d°C (power
%uW)
Could not open CAN
CAN interface open
interface (error %d)
error
CAN error %d
CAN error
(remote flags %02X,
dbCan flags %02X)
Location
Possible reasons
Amp
Amp software error.
DSP
Software error or
wrong device type
detected.
DSP
Software error.
DSP
DSP or software
error.
DSP
DSP defect or
software error.
DSP
Software error.
(External: AP data file
Software error.
invalid)
Amp
Amp defect.
Amp
Amp firmware does
not support the Amp
hardware.
Amp
Poor cooling.
Amp
cabling or Amp
defect.
Amp
Poor cooling.
Amp
Amp defect.
Amp
Poor cooling.
DSP
DSP defect or
software error.
(External: CAN
CAN cabling or
cabling), RemId
multiple RemIds.